SLAAED9 November 2023 TAA5412-Q1 , TAC5311-Q1 , TAC5312-Q1 , TAC5411-Q1 , TAC5412-Q1
In some applications, waiting for the input from the host processor is desired before powering back up after a fault occurs and MICBIAS and ADC channels are shut down. For this purpose, the PD_ON_FLT_RCV_CFG bit in INT_CFG, P0_R66 can be set to 1 to enable manual recovery mode. In this mode, the device waits for a write of 1 to the MAN_RCV_PD_FLT_CHK bit in the DIAG_CFG10, P1_R80 register before initiating the start-up sequence. The proper sequence for initiating a manual recovery is as follows:
Do not skip step 2 in this sequence, otherwise the device can fail to start up properly, even if faults are no longer present.