Figure 7-5 shows the current test pattern (left) and the detection error (right) under 25°C. You can find that this solution can control the error within 5 mA in the range of ±2000 mA. The error percentage is below than ±0.25% at ±2000 mA.

GUID-8532AFB8-2EA0-4399-9A4C-B9A0C2273ADC-low.png Figure 7-5 Current Test Pattern and its Error Under 25°C