Test Overview

The DAC121S101-SEP was tested according to MIL-STD-883, Test Method 1019.9. For this testing, Condition A was used. The DAC121S101-SEP samples were irradiated at a high dose rate of 50-300 rad(Si)/s up to 30 krad(Si) and then put through full electrical parametric testing on the production Automated Test Equipment (ATE). The samples were functional and passed all electrical parametric tests with readings within data sheet electrical specification limits.