SLAK034 December   2024 DAC121S101-SEP

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Device Details
  5. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Biased
    4. 2.4 Test Configuration and Condition
  6. 3Total Ionizing Dose (RHA) Characterization Test Results
    1. 3.1 Total Ionizing Dose RHA Characterization Summary Results
      1. 3.1.1 VDD Current HDR
      2. 3.1.2 Power Down Current HDR
  7. 4Total Ionizing Dose HDR Report

Device Details

Table 1-1 lists the device information used for TID HDR characterization and qualification.

Table 1-1 Device and Exposure Details
TID HDR Details: up to 30 krad(Si)
TI Device NumberDAC121S101-SEP
Package8-pin DGK (VSSOP)
TechnologyCMOS
Die Lot Number3006584CUA
A/T Lot Number / Lot Trace Code3307938MY1/3AAZPPK
Quantity Tested5 irradiated devices + 1control
Lot Accept/RejectDevices passed 30 krad(Si)
HDR Radiation FacilityTexas Instruments CLAB, Dallas, TX
HDR Dose Level30 krad(Si)
HDR Dose Rate171 rad(Si)/second
HDR Radiation SourceGammacell (GR420) Co-60
Irradiation TemperatureAmbient, room temperature