SLDA058 March 2021 TUSS4470
TX Setting | Short Range Value | Mid-Range Value | RX Setting | Value | Output Setting | Short Range Value | Mid-Range Value |
---|---|---|---|---|---|---|---|
BURST_PULSE | 1-3 | 10 | BPF_HPF_FREQ | 400p | ECHO_INT_ COMP_EN |
Disabled | Disabled |
HALF_BRG_ MODE |
Enabled | Disabled | LOGAMP_DIS_ LAST_GM |
Disabled | Record (GUI record time) | 12 ms | 12 ms |
Frequency | 1 MHz | LOGAMP_DIS_ FIRST_GM |
Disabled | ||||
BPF_BYPASS | Enabled |
Evaluation Notes:
The band pass filter is configurable for use up to 500 kHz. For 1 MHz transducer operation, BPF_BYPASS should be set to one, converting the BPF to a HPF with cut-off frequency BPF_HPF_FREQ set to 400 kHz. In short range water-coupled applications, the dynamic range of the received echo should be sufficient without the log amplifier enabled. Probing VOUT with an oscilloscope will show more accurate results than the GUI VOUT plot due to the higher sampling rate of the scope. The ADC used to sample VOUT by the host MCU samples at 1 MSPS.