SLLA543 January   2021 THVD2410 , THVD2450

 

  1.   Trademarks
  2. 1Overview
  3. 2Functional Safety Failure In Time (FIT) Rates
  4. 3Failure Mode Distribution (FMD)
  5. 4Pin Failure Mode Analysis (Pin FMA)

Overview

This document contains information for RS-485 transceivers THVD2450 and THVD2410 (SOIC, VSON, VSSOP packages) to aid in a functional safety system design. Information provided are:

  • Functional Safety Failure In Time (FIT) rates of the semiconductor component estimated by the application of industry reliability standards
  • Component failure modes and their distribution (FMD) based on the primary function of the device
  • Pin failure mode analysis (Pin FMA)

Figure 1-1 shows the device functional block diagram for reference.

GUID-4E039341-F1C0-4848-83D9-07484A17AE5D-low.gif Figure 1-1 Functional Block Diagram

THVD2450 and THVD2410 were developed using a quality-managed development process, but was not developed in accordance with the IEC 61508 or ISO 26262 standards.