SLLA579 January 2022 ISOUSB211
Figure 5-1 shows the setup for measuring the far-end eye-mask as specified by the USB 2.0 standard. The ISOUSB211 is placed next to the transmitter, and a USB receptacle connects the FR4 trace to a 5-m USB cable. We used a 5-m cable to account for the worst-case cable loss that is specified by the USB 2.0 standard. The signal is measured at the other end of the 5-m cable for its far-end eye performance.
Figure 5-2 through Figure 5-7 show the eye-diagram measurements with Figure 5-1 setup that uses the transmitter pre-emphasis to compensate for the trace and cable losses. The receiver equalizer is set to 00 throughout the measurements. The transmitter pre-emphasis performances are evaluated by multiplying the EW with EH as shown in Figure 5-7.