SLLS567F May 2003 – July 2024 MAX211
PRODUCTION DATA
PARAMETER | TEST CONDITIONS | MIN | TYP(1) | MAX | UNIT | ||
---|---|---|---|---|---|---|---|
ICC | Supply current | No load, | See Figure 8-1 | 14 | 20 | mA | |
Shutdown supply current (DB package) | TA = 25°C | See Figure 6-1 | 5 | 10 | µA | ||
Shutdown supply current (DW package) | TA = 25°C | See Figure 6-1 | 1 | 20 | µA |