SLOU579 August   2024 TSD5402-Q1

 

  1.   1
  2.   Description
  3.   Get Started
  4.   Features
  5.   Applications
  6.   6
  7. 1Evaluation Module Overview
    1. 1.1 Introduction
    2. 1.2 Kit Contents
    3. 1.3 Specification
    4. 1.4 Device Information
  8. 2Hardware
    1. 2.1 Hardware Overview
    2. 2.2 Setup
    3. 2.3 Interfaces
    4. 2.4 Settings Via I2C
      1. 2.4.1 TSD5402-Q1 Gain
      2. 2.4.2 TSD5402-Q1 PWM Switching Frequencies
      3. 2.4.3 TSD5402-Q1 Power Guard Protection Circuitry
  9. 3Software
    1. 3.1 Software Overview
      1. 3.1.1 PurePathâ„¢ Console 3 (PPC3) Access and Description
      2. 3.1.2 Using the PPC3 Plugin
  10. 4Hardware Design Files
    1. 4.1 TSD5402Q1EVM Schematics
    2. 4.2 TSD5402Q1EVM PCB Layouts
    3. 4.3 Bill of Materials
  11. 5Additional Information
    1. 5.1 Trademarks

Setup

This section describes the setup and start up procedure for the TSD5402Q1EVM. Have the equipment and accessories listed previously in this document available.

  1. On the desktop or laptop PC running Windows, open the PPC3 GUI.
  2. Connect 14.4 VDC Power Supply Unit(PSU) to TSD5402Q1EVM via the J2 screw-in terminal block connector.
  3. Connect the input signal source and output loads to TSD5402Q1EVM via the J2 screw-in terminal block connector.
  4. Connect micro-USB cable from PC to the EVM
  5. Set the switches (STANDBY, MUTE) to normal positions.
  6. Turn on the power supply.
  7. Analog signal source: this can be the analog test equipment or arbitrary signal generator.
  8. At this point, 3.3V LED, and USB-LOCK LED are on.
  9. On the PPC3 window, launch TSD5402 plugin.
  10. The load can now be driven by the analog input signal.