SLUAAQ8 august 2023 TPS54202 , TPS563201 , TPS62933
In the applications where Vout is close to Vin, large duty is needed to support normal regulation. Due to minimum off-time limit, if switching frequency does not change, the maximum duty-cycle is fixed. Large Duty Operation extends the high-side FET on-time, thus decreasing switching frequency and allowing large duty cycles to be maintained. The Large Duty Cycle Operation With the TPS568230 application note describes the details.
Some parts support 100% duty-cycle mode, high-side FET is continuously switched on as long as the BOOT capacitor voltage is higher than preset UVLO threshold.