This report discusses the results of the Total Ionizing Dose (TID) testing for the QML Class V certified Texas Instruments (TI) UC1825B-SP (596R876806VYC).
The study helps determine the TID effects under low dose rate (LDR) up to 100krad(Si). The results show that all samples are fully functional after being exposed up to 100krad(Si).
All trademarks are the property of their respective owners.