SLUSFF2 October 2024 UCG28826
ADVANCE INFORMATION
The UCG28826 includes frequency clamp to limit the maximum switching frequency. This is useful during design optimizations to pass emissions standards and reduce switching losses by limiting the switching frequency to a certain value. The device offers four max. frequency clamp settings at 140kHz, 200kHz, 250kHz and 500kHz which can be selected with a resistor from FCL pin to ground as per values in Table 6-3. In no condition does the switching frequency exceed the chosen value of clamp frequency, except in burst mode when clamp frequency is set to 250kHz.
The minimum switching frequency is also clamped to a fixed 25kHz to prevent switching in the audible frequency range and noise from the flyback converter. Such low switching frequency can occur during operation in higher valleys or frequency foldback mode.