SLUU535A September 2011 – January 2022 TPS40400
All Jumper selections should be made prior to applying power to the EVM. User can configure this EVM as per following configurations.
JUMPERS JP1 AND JP2 | DISCRETE SENSE WIRES | RESULT | USED FOR |
---|---|---|---|
Installed | Do not use | Default. Sense points are at the output connectors of the EVM. | Most testing. |
Not installed | Not installed | Sense points are at the output connectors of the EVM, but through R7 and R18. Regulation will be degraded. | Not usually desired in this configuration. |
Not installed | Installed and connected to the output voltage at the location where regulation is desired | Regulation will be at the far end location of the added discrete sense wires, usually desired to be the point of load. | Tight regulation of output voltage at a remote location, subject to the limitations mentioned in 5.4.3. |