SLUUBJ1B february 2017 – july 2023 TPS2373
Table 5-1 lists the EVM connector functionality and Table 5-2 describes the test point availability. Table 5-3 describes the jumper selections of the EVM.
Connector | Label | Description |
---|---|---|
J1 | ETHERNET POWER | PoE input. Connect to PSE power and data source. |
J2 | DATA | Ethernet data passthrough. Connect to downstream Ethernet device. |
J13 | Output | Output connector to load. |
J3 | DC/DC Input | DC/DC converter input bypassing the PoE front-end. Connect a DC power supply 40-57. |
Test Point | Label | Description |
---|---|---|
TP1 | PAIR 12 | Data pair from Pins 1 and 2 of J1 |
TP2 | PAIR 36 | Data pair from Pins 3 and 6 of J1 |
TP3 | PAIR 45 | Data pair from Pins 4 and 5 of J1 |
TP4 | PAIR 78 | Data pair from Pins 7 and 8 of J1 |
TP5 | EARTH | Connect to earth ground when available |
TP7 | MPS_DUTY | MPS_DUTY pin of the TPS2373-4 |
TP9, TP10 | VDD | Input voltage of PD system |
TP11 | TPH | TPH output of the TPS2373-4 |
TP12 | TPL | TPL output of the TPS2373-4 |
TP13 | BT | BT output of the TPS2373-4 |
TP14 | PG | Power Good output of the TPS2373-4 |
TP15, TP25 | RTN | Load side return voltage |
TP16 | AMPS_CTL | AMPS_CTL output voltage |
TP17 | VSS1 | EMI filter return side voltage |
TP18 | REF | Reference pin output voltage of the TPS2373-4 |
TP19 | VSS | PD side return voltage |
TP20 | VOUT | Converter output voltage |
TP21 | VDS | Drain voltage of the primary FET of the converter |
TP22 | GATE | Gate voltage of the primary FET of the converter |
TP23 | GND | Secondary ground connection |
TP24 | VCIN | Bias winding circuit output voltage |
TP26 | FB | Feedback pin voltage of U2 PWM controller |
TP27 | VIN | Startup input voltage of U2 (open circuited) |
TP28 | LOOP | Feedback connection for frequency response measurements |
TP29 | UVLO_SEL | Select UVLO of U1 (open circuited) |
TP30 | VCOUT | Output voltage of advanced startup of U1 |
Jumper | Description |
---|---|
J4 | Jump to power TPH/TPL/BT through the bias winding. Or open to power through external circuit |
J5 | Automatic MPS duty cycle selection |
J6 | Jump for adapter priority |
J7 | CLSA selection |
J10 | CLSB selection |
J11 | Can be used to measure port current; otherwise, J11 must be shorted |
J12 | Jump to add auto MPS current |
J15 | Jump to power output LED |