Figure 1-1 highlights the user interface items associated with the EVM. The VIN and PGND terminal blocks (J1 and J3) are used for connection to the host input supply and the VOUT and PGND terminal blocks (J4, J10, J13, J16) are used for connection to the load. These terminal blocks can accept up to 16-AWG wire.
Device | Output Voltage | Output Current Range | Input Voltage |
---|---|---|---|
U1 Dual Output | VOUT1 = 0.8 V, 1.0 V, 1.2 V, 1.8 V, or 3.3 V | 0 to 6 A per output | VIN = 4.5 V to 15 V |
VOUT2 = 0.9 V, 1.1 V, 1.2 V, 1.5 V, or 2.5 V | |||
U2 Parallel Output | VOUT3 = 0.9 V, 1.0 V, 1.1 V, 1.2 V, or 1.8 V | 0 to 12 A |