SLVAFL4 august 2023 TPS61299
To see the benefits of fast transient performance in smart band applications visually, the following assumptions are made based on the actual market application and TPS61299 application with fast transient mode.
where:
The energy loss of LED is:
The standby time of the actual market application is :
Extended standby time is:
t1 is the standby time of market application and t2 is the standby time of TPS61299 application
Table 3-1 shows the parameter of the actual market application and TPS61299 application with fast transient mode:
Parameter | Value | Parameter | Value | Parameter | Value |
---|---|---|---|---|---|
tpwm1 | 60 us | f | 50Hz | PLED | 0.3 mW |
tpwm2 | 120 us | Ebat | 450mAh | Psys | 1.159 mW |
According to the parameter and equation, the energy loss of the actual market application and TPS61299 application with fast transient mode are 0.18 mW, 0.09 mW separately. The standby time of the actual market application is 14.00 days and the standby time of TPS61299 application with fast transient mode is 15.01 days, so TPS61299 application with fast transient mode can extent standby time 1.01 days.