SLVK182 December 2024 DRV8351-SEP
The DRV8351-SEP samples were irradiated at a high dose rate of 177.47rad(Si) / s up to 30krad(Si) and then put through full electrical parametric testing on the production Automated Test Equipment (ATE). The samples were functional and passed all electrical parametric tests with readings within data sheet electrical specification limits.