SLVSDU0B September 2017 – September 2019 BQ25910
PRODUCTION DATA.
The device monitors the outer switching FET current on a cycle-by-cycle basis . If an over-current is detected, the device responds by forcing the switching FETs to immediately discharge the inductor current and attempt current ramp-up once again.