SLVU469B June   2011  – May 2021 TPS65253

 

  1.   Trademarks
  2. 1Introduction
  3. 2Background
  4. 3Schematic
  5. 4Placement
  6. 5Bench Test Setup Conditions
    1. 5.1 Headers Description and Jumper Placement
    2. 5.2 Jumpers
    3. 5.3 Test Points and Placement
  7. 6Power-Up Procedure
  8. 7Bill of Materials
  9. 8Revision History

Test Points and Placement

Buck converter outputs are white and have a label for easy location. Close to any of these test points there are black ground test points to allow for DVM measurement or to use a metal exposed scope probe to reduce common mode noise measurements. All test points are described in Table 5-2.

Table 5-2 Test Points and Placement
TEST
POINT
NAMESIGNALCOLORCOMMENT
TP1, TPS, TP3, TP4, TP5GNDGroundBlack
TP8VINInput supplyWhite
TP9, TP9AVOUT1Buck1 outputWhite
TP9BInput for gain-phase measurement Buck1WhiteNormally not used
TP11, TP11AVOUT2Buck2 outputWhite
TP11BInput for gain-phase measurement Buck2WhiteNormally not used
TP20Low_PLow Power inputWhite
TP24PGOODPower Good
(open drain connected to Buck1 output)
White