The following test equipment is needed to test the
LM5127EVM-FLEX as shown in the Figure 4-1 and in the standard configuration according to Section 6.
- Power supply: The input voltage source (VIN)
should be a variable supply. The power supply should source 3 V to 42 V and
be able to supply more than 30 A or current.
- Electronic Load
- Electronic load 2: Capable of at least 5 A at a voltage of 5
V
- Electronic load 3: Capable of at least 7 A at a voltage of 3.3
V
- Multimeters
- Voltmeter 1
(VIN): Capable of measuring the input voltage
range up to 42 V
- Voltmeter 2
(VOUT2): Capable of measuring output voltage of
5 V
- Voltmeter 3
(VOUT3): Capable of measuring output voltage of
3.3 V
- Ammeter 1
(IIN): Capable of 30 A DC measurement. A shunt
resistor may also be used to measure the input current.
- Ammeter 2
(IOUT2): Capable of at least 5 A DC
measurement
- Ammeter 3
(IOUT3): Capable of at least a 7 A DC
measurement