Use the following instructions to power up the TPS25985 eFuse with ENABLE:
Configure the jumper J2 position to the desired slew rate mentioned in Table 4-3.
Configure the jumpers J5 and J7 positions to the desired current limits during start-up as mentioned in Table 4-3.
Configure the Jumper J6 position to desired reference voltage for overcurrent protection and active current sharing as mentioned in Table 4-3.
Set the input supply voltage VIN to 12 V and current limit to 100 A.
Connect a load of 1.2 Ω between VOUT (Connector T2) and PGND (Connector T3).
Connect the input supply between VIN (Connector T1) and PGND (Connector T3).
Turn on the power supply by keeping the device disabled using the switch SW1.
Enable the eFuses by releasing the switch SW1.
Observe the waveform at VOUT (TP4) and input current using an oscilloscope to measure the slew rate and rise time of the VOUT with a given input voltage of 12 V.
Figure 5-4 shows the start-up profile of TPS25985 eFuse with ENABLE using two (2) devices in parallel.
Figure 5-4 TPS25985 eFuse Start-up Profile with ENABLE (VIN = 12 V, EN Stepped Up from 0 V to 3 V, COUT = 18.47 mF, RLOAD = 1.2 Ω, and CDVDT = 33 nF)