HICCUP Mode

For the design, the value of the hiccup capacitor used is 100 nF. Based on this value, the delay and hiccup times of the converter after an overcurrent are detected can be calculated using Equation 9 and Equation 10, respectively.

Equation 9. t d e l a y =   C H I C C   x   0.6   V   80   μ A =     100   n F   x   0.6   V     80   μ A =     75   μ s