Over the recommended operating junction temperature range of –40°C to 150°C
(unless otherwise noted)
|
MIN |
NOM |
MAX |
UNIT |
Input voltage range after startup(1) |
3.8 |
|
36 |
V |
Output voltage range |
5
V(2) |
0 |
|
5.5 |
V |
3.3
V(2) |
0 |
|
3.63 |
Output adjustment range(3)for LM53600-Q1-ADJ (2), LM53601-Q1-ADJ(2) |
3.3 |
|
6 |
V |
Load current range |
LM53600-Q1 |
0 |
|
650 |
mA |
LM53601-Q1 |
0 |
|
1000 |
Operating junction temperature(4) |
–40 |
|
150 |
°C |
(1) An extended input voltage range to 3.55 V is possible; see
Section 7.6. See input UVLO in
Section 7.5 for startup conditions.
(2) Output voltage should not be allowed to fall below 0 V during
normal operation.
(3) The LM53600-Q1 and LM53601-Q1 devices can operate outside of
the listed range output voltage range. For output voltage outside of the listed
range, contact Texas Instruments concerning alternate application circuit BOM
and additional operational limitations such as higher IQ.
(4) High junction temperatures degrade operating lifetimes.
Operating lifetime is de-rated for junction temperatures greater than
125°C.