SNIS233A February   2024  – July 2024 TMP110

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Related Products
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 I2C Interface Timing
    7. 6.7 Timing Diagrams
    8. 6.8 Typical Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Digital Temperature Output
      2. 7.3.2 Decoding Temperature Data
      3. 7.3.3 Temperature Limits and Alert
    4. 7.4 Device Functional Modes
      1. 7.4.1 Continuous-Conversion Mode
      2. 7.4.2 One-Shot Mode
    5. 7.5 Programming
      1. 7.5.1 Serial Interface
      2. 7.5.2 Bus Overview
      3. 7.5.3 Device Address
      4. 7.5.4 Bus Transactions
        1. 7.5.4.1 Writes
        2. 7.5.4.2 Reads
        3. 7.5.4.3 General Call Reset Function
        4. 7.5.4.4 SMBus Alert Response
        5. 7.5.4.5 Time-Out Function
        6. 7.5.4.6 Coexist on I3C Mixed Bus
  9. Register Map
    1. 8.1 Temp_Result Register (address = 00h) [reset = xxxxh]
    2. 8.2 Configuration Register (address = 01h) [reset = 60A0h]
    3. 8.3 TLow_Limit Register (address = 02h) [reset = 4B00h]
    4. 8.4 THigh_Limit Register (address = 03h) [reset = 5000h]
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Equal I2C Pullup and Supply Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curve
      4. 9.2.4 Power Supply Recommendations
    3. 9.3 Layout
      1. 9.3.1 Layout Guidelines
      2. 9.3.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Documentation Support
      1. 10.1.1 Related Documentation
    2. 10.2 Receiving Notification of Documentation Updates
    3. 10.3 Support Resources
    4. 10.4 Trademarks
    5. 10.5 Electrostatic Discharge Caution
    6. 10.6 Glossary
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information

Configuration Register (address = 01h) [reset = 60A0h]

This register is used to configure the operation of the TMP110 and also provides the alert status when ALERT pin is not available on the pin-out.

Return to Register Map.

Table 8-7 Configuration Register
15141312111098
One_ShotReservedFault[1:0]PolarityAlert_ModeShutdown
R/W-0bR-11bR/W-00bR/W-0bR/W-0bR/W-0b
76543210
Conversion_Rate[1:0]AlertExtended_ModeReserved
R/W-10bR-1bR/W-0bR-0000b
Table 8-8 Configuration Register Field Description
BitFieldTypeResetDescription
15 One_ShotR/W0bOne-shot conversion trigger applicable in shutdown mode only. In continuous conversion mode the bit reads 0b. In shutdown mode the bit reads 1b. Triggering a one-shot conversion happens only when the TMP110 is in shutdown mode.
0b = Active conversion ongoing
1b = Trigger a one-shot conversion or active conversion complete
14:13ReservedR11bReserved
12:11Fault[1:0]R/W00bThe fault bit is used to count the number of consecutive conversions for which the alert condition exists before the ALERT pin is asserted or status bit is set.
00b = 1 fault
01b = 2 faults
10b = 4 faults
11b = 6 faults
10PolarityR/W0bThe polarity bit allows the host to adjust the polarity of the ALERT pin/flag output.
0b = ALERT pin/flag output is active low
1b = ALERT pin/flag output is active high
9Alert_ModeR/W0bThe alert mode bit indicates the how the temperature limits operate.
0b = Comparator mode
1b = Alert mode
8ShutdownR/W0bThe shutdown bit is used to change the device conversion mode.
0b = Continuous conversion mode
1b = Shutdown mode
7:6Conversion_Rate[1:0]R/W10bThe conversion rate bits configure the TMP110 conversion period. The default is conversion every 250ms.
00b = 4s / 0.25Hz
01b = 1s / 1Hz
10b = 0.25s / 4Hz
11b = 0.125s / 8Hz
5Alert flagR1bThe alert is a read-only bit which provides the information about the alert status in comparator mode and is not affected by Alert_Mode setting. The polarity bit affects the alert flag.
4Extended_ModeR/W0bThe extended mode bit configures the temperature format.
0b = Normal format with 12-bit
1b = Extended format with 13-bit
3:0ReservedR0000bReserved