SNLA385 September 2021 DP83561-SP , DP83620 , DP83630 , DP83640 , DP83822H , DP83822HF , DP83822I , DP83822IF , DP83825I , DP83826E , DP83826I , DP83843 , DP83847 , DP83848-EP , DP83848-HT , DP83848C , DP83848H , DP83848I , DP83848J , DP83848K , DP83848M , DP83848Q-Q1 , DP83848T , DP83848VYB , DP83848YB , DP83849C , DP83849I , DP83849ID , DP83849IF , DP83867CR , DP83867CS , DP83867E , DP83867IR , DP83867IS , DP83869HM
This application brief provides a simple and easy method to validate if the test case passes even though the test report shows a test case failure. When the test case fails after validating the formula, further hardware analysis must be made to find the root cause of the failure. From TI experience the following can cause the Ethernet compliance test case to fail:
Additional components on the MDI routing to Magentics: ESD or other components with high capacitance and impedance added on the path will be evaluated.
Post Ethernet questions to the TI E2E™ forum.