4.4.3.2 Remove External Factor on Cable or Link Partner
Change the Link Partner to the
same model as DUT and perform a test
Use a conducted model box or
plate that are connected to earth ground for strong shielding on Link Partner
board (isolates effect of the Link Partner)
Use a conducted model box or
plate that are connected to earth ground for strong shielding on the cable and
Link Partner (isolates effect of both cable and Link Partner)
Disconnect the cable and program
the Ethernet PHY into loopback, noting any link down or failure
Further confirms if DUT
is the root cause of RI failure