SNVU754A October   2021  – November 2021 LM5013-Q1

 

  1.   Trademarks
  2. 1General TI High Voltage Evaluation User Safety Guidelines
  3. 2Overview
    1. 2.1 LM5013-Q1 Asynchronous Buck Converter
  4. 3LM5013-Q1 Evaluation Module
    1. 3.1 Quick Start Procedure
    2. 3.2 Detailed Descriptions
  5. 4Schematic
  6. 5PCB Layout
  7. 6Bill of Materials
  8. 7Performance Curves
  9. 8Revision History

Quick Start Procedure

  1. Connect the voltage supply between VIN and GND connectors using short wires.
  2. Connect the load of the converter between VOUT and GND connectors using short wires.
  3. Set the supply voltage (VVIN) at an appropriate level between 15-V to 100-V. Set the current limit of the supply to an appropriate level as well.
  4. Turn on the power supply. The EVM powers up and provides VOUT = 12-V.
  5. Monitor the output voltage while increasing the load current to max.

    See Figure 3-1 for the location of the connectors.

GUID-20210726-CA0I-24R2-F9B0-RFMGGQ5N5JRR-low.jpgFigure 3-1 LM5013-Q1 EVM Top View
GUID-9D3BB23E-D283-46D2-A120-21C5ACA20B59-low.gif