SPRUHJ1I January 2013 – October 2021 TMS320F2802-Q1 , TMS320F28026-Q1 , TMS320F28026F , TMS320F28027-Q1 , TMS320F28027F , TMS320F28027F-Q1 , TMS320F28052-Q1 , TMS320F28052F , TMS320F28052F-Q1 , TMS320F28052M , TMS320F28052M-Q1 , TMS320F28054-Q1 , TMS320F28054F , TMS320F28054F-Q1 , TMS320F28054M , TMS320F28054M-Q1 , TMS320F2806-Q1 , TMS320F28062-Q1 , TMS320F28062F , TMS320F28062F-Q1 , TMS320F28068F , TMS320F28068M , TMS320F28069-Q1 , TMS320F28069F , TMS320F28069F-Q1 , TMS320F28069M , TMS320F28069M-Q1
In order to operate at low speeds, first let us discuss the low speed operation with no mechanical load. The lowest speed we can control with no load can be seen visually in the motor rotation as well as in the current waveform. For example, running the motor under test down to 30 RPM, or 2 Hz, is possible with a speed variation of 30 ±3 RPM. However, in order to get to a speed fairly constant we must have the speed controller responsive enough to compensate against speed variations.