SPRUIY4B February 2023 – May 2024 TMS320F2800152-Q1 , TMS320F2800153-Q1 , TMS320F2800154-Q1 , TMS320F2800155 , TMS320F2800155-Q1 , TMS320F2800156-Q1 , TMS320F2800157 , TMS320F2800157-Q1
To achieve safety diagnostic, Missing Clock Detection (MCD) can be used.
Table 4-12 lists the details.
Clock Failure Detection Circuitry |
Clocks Detected | Time for Detection (in Cycles) |
Limitations |
---|---|---|---|
Missing Clock Detection (MCD) | INTOSC2, XTAL/X1 | 8192 INTOSC1 cycles | Cannot detect INTOSC1 clock failure. |