SPRUJ17H March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
(FREQ = 250 MHz)
Program CPTS GCD register with the value of 0x111 in-order to switch to a new desired frequency, MSS_RCM.CPTS_CLK_DIV_VAL.CLKDIV = 0x111
Poll for the CURRDIVR field of corresponding status register to reflect its new frequency change, MSS_RCM.CPTS_CLK_STATUS.CURRDIVIDER = 0x01
Update the CPTS GCM register with the value of 0x333 to select PLL_PER_CLKOUT1 as its source, MSS_RCM.CPTS_CLK_SRC_SEL.CLKSRCSEL = 0x333
Poll for the CLKINUSE field of corresponding status register to reflect its new frequency change, MSS_RCM.CPTS_CLK_STATUS.CLKINUSE = 0x08