SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
S/W control to Powers down the L2 Bank 0 and disconnect from Interconnect. AON AGOOD 0 or ISO =1 causes bus disconnect.
Return to Summary Table
Instance Name | Physical Address |
---|---|
MSS_RCM | 5320 8700h |
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 |
RESERVED | |||||||
NONE | |||||||
0h | |||||||
23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
RESERVED | |||||||
NONE | |||||||
0h | |||||||
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
RESERVED | MSS_L2_BANKA_PD_CTRL_AGOODIN | ||||||
NONE | R/W | ||||||
0h | 7h | ||||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RESERVED | MSS_L2_BANKA_PD_CTRL_AONIN | RESERVED | MSS_L2_BANKA_PD_CTRL_ISO | ||||
NONE | R/W | NONE | R/W | ||||
0h | 7h | 0h | 0h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
31:11 | RESERVED | NONE | 0h | Reserved |
10:8 | MSS_L2_BANKA_PD_CTRL_AGOODIN | R/W | 7h | SW control for power signal 'AGOODIN' for MSS_L2_BANKA |
7 | RESERVED | NONE | 0h | Reserved |
6:4 | MSS_L2_BANKA_PD_CTRL_AONIN | R/W | 7h | SW control for power signal 'AONIN' for MSS_L2_BANKA |
3 | RESERVED | NONE | 0h | Reserved |
2:0 | MSS_L2_BANKA_PD_CTRL_ISO | R/W | 0h | SW control for power signal 'ISO' for MSS_L2_BANKA. |