SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
Receive ECC value register.
Return to Summary Table
Instance Name | Physical Address |
---|---|
FSI_RX0 | 5029 0044h |
FSI_RX1 | 5029 1044h |
FSI_RX2 | 502B 0044h |
FSI_RX3 | 502B 1044h |
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
RESERVED_1 | |||||||
R | |||||||
0h | |||||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RESERVED_1 | ECC_VAL | ||||||
R | R/W | ||||||
0h | 0h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
15:7 | RESERVED_1 | R | 0h | Reserved |
6:0 | ECC_VAL | R/W | 0h | ECC Value for SEC-DED check This field contains the ECC value to be used for SEC-DED either for 16-bit or 32-bit data in the RX_ECC_DATA register. |