SPRUJ42E March 2022 – October 2024 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1
PRODUCTION DATA
Digital Compare Filter Offset Register .
Return to Summary Table
Instance Name | Physical Address |
---|---|
EPWM0_G0 | 5000 0192h |
EPWM0_G1 | 5004 0192h |
EPWM0_G2 | 5008 0192h |
EPWM0_G3 | 500C 0192h |
EPWM1_G0 | 5000 1192h |
EPWM1_G1 | 5004 1192h |
EPWM1_G2 | 5008 1192h |
EPWM1_G3 | 500C 1192h |
EPWM2_G0 | 5000 2192h |
EPWM2_G1 | 5004 2192h |
EPWM2_G2 | 5008 2192h |
EPWM2_G3 | 500C 2192h |
EPWM3_G0 | 5000 3192h |
EPWM3_G1 | 5004 3192h |
EPWM3_G2 | 5008 3192h |
EPWM3_G3 | 500C 3192h |
EPWM4_G0 | 5000 4192h |
EPWM4_G1 | 5004 4192h |
EPWM4_G2 | 5008 4192h |
EPWM4_G3 | 500C 4192h |
EPWM5_G0 | 5000 5192h |
EPWM5_G1 | 5004 5192h |
EPWM5_G2 | 5008 5192h |
EPWM5_G3 | 500C 5192h |
EPWM6_G0 | 5000 6192h |
EPWM6_G1 | 5004 6192h |
EPWM6_G2 | 5008 6192h |
EPWM6_G3 | 500C 6192h |
EPWM7_G0 | 5000 7192h |
EPWM7_G1 | 5004 7192h |
EPWM7_G2 | 5008 7192h |
EPWM7_G3 | 500C 7192h |
EPWM8_G0 | 5000 8192h |
EPWM8_G1 | 5004 8192h |
EPWM8_G2 | 5008 8192h |
EPWM8_G3 | 500C 8192h |
EPWM9_G0 | 5000 9192h |
EPWM9_G1 | 5004 9192h |
EPWM9_G2 | 5008 9192h |
EPWM9_G3 | 500C 9192h |
EPWM10_G0 | 5000 A192h |
EPWM10_G1 | 5004 A192h |
EPWM10_G2 | 5008 A192h |
EPWM10_G3 | 500C A192h |
EPWM11_G0 | 5000 B192h |
EPWM11_G1 | 5004 B192h |
EPWM11_G2 | 5008 B192h |
EPWM11_G3 | 500C B192h |
EPWM12_G0 | 5000 C192h |
EPWM12_G1 | 5004 C192h |
EPWM12_G2 | 5008 C192h |
EPWM12_G3 | 500C C192h |
EPWM13_G0 | 5000 D192h |
EPWM13_G1 | 5004 D192h |
EPWM13_G2 | 5008 D192h |
EPWM13_G3 | 500C D192h |
EPWM14_G0 | 5000 E192h |
EPWM14_G1 | 5004 E192h |
EPWM14_G2 | 5008 E192h |
EPWM14_G3 | 500C E192h |
EPWM15_G0 | 5000 F192h |
EPWM15_G1 | 5004 F192h |
EPWM15_G2 | 5008 F192h |
EPWM15_G3 | 500C F192h |
EPWM16_G0 | 5001 0192h |
EPWM16_G1 | 5005 0192h |
EPWM16_G2 | 5009 0192h |
EPWM16_G3 | 500D 0192h |
EPWM17_G0 | 5001 1192h |
EPWM17_G1 | 5005 1192h |
EPWM17_G2 | 5009 1192h |
EPWM17_G3 | 500D 1192h |
EPWM18_G0 | 5001 2192h |
EPWM18_G1 | 5005 2192h |
EPWM18_G2 | 5009 2192h |
EPWM18_G3 | 500D 2192h |
EPWM19_G0 | 5001 3192h |
EPWM19_G1 | 5005 3192h |
EPWM19_G2 | 5009 3192h |
EPWM19_G3 | 500D 3192h |
EPWM20_G0 | 5001 4192h |
EPWM20_G1 | 5005 4192h |
EPWM20_G2 | 5009 4192h |
EPWM20_G3 | 500D 4192h |
EPWM21_G0 | 5001 5192h |
EPWM21_G1 | 5005 5192h |
EPWM21_G2 | 5009 5192h |
EPWM21_G3 | 500D 5192h |
EPWM22_G0 | 5001 6192h |
EPWM22_G1 | 5005 6192h |
EPWM22_G2 | 5009 6192h |
EPWM22_G3 | 500D 6192h |
EPWM23_G0 | 5001 7192h |
EPWM23_G1 | 5005 7192h |
EPWM23_G2 | 5009 7192h |
EPWM23_G3 | 500D 7192h |
EPWM24_G0 | 5001 8192h |
EPWM24_G1 | 5005 8192h |
EPWM24_G2 | 5009 8192h |
EPWM24_G3 | 500D 8192h |
EPWM25_G0 | 5001 9192h |
EPWM25_G1 | 5005 9192h |
EPWM25_G2 | 5009 9192h |
EPWM25_G3 | 500D 9192h |
EPWM26_G0 | 5001 A192h |
EPWM26_G1 | 5005 A192h |
EPWM26_G2 | 5009 A192h |
EPWM26_G3 | 500D A192h |
EPWM27_G0 | 5001 B192h |
EPWM27_G1 | 5005 B192h |
EPWM27_G2 | 5009 B192h |
EPWM27_G3 | 500D B192h |
EPWM28_G0 | 5001 C192h |
EPWM28_G1 | 5005 C192h |
EPWM28_G2 | 5009 C192h |
EPWM28_G3 | 500D C192h |
EPWM29_G0 | 5001 D192h |
EPWM29_G1 | 5005 D192h |
EPWM29_G2 | 5009 D192h |
EPWM29_G3 | 500D D192h |
EPWM30_G0 | 5001 E192h |
EPWM30_G1 | 5005 E192h |
EPWM30_G2 | 5009 E192h |
EPWM30_G3 | 500D E192h |
EPWM31_G0 | 5001 F192h |
EPWM31_G1 | 5005 F192h |
EPWM31_G2 | 5009 F192h |
EPWM31_G3 | 500D F192h |
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
DCFOFFSET | |||||||
R/W | |||||||
0h | |||||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
DCFOFFSET | |||||||
R/W | |||||||
0h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
15:0 | DCFOFFSET | R/W | 0h | Blanking Window Offset These 16-bits specify the number of TBCLK cycles from the blanking window reference to the point when the blanking window is applied. The blanking window reference is either period or zero as defined by the DCFCTL[PULSESEL] bit. This offset register is shadowed and the active register is loaded at the reference point defined by DCFCTL[PULSESEL]. The offset counter is also initialized and begins to count down when the active register is loaded. When the counter expires, the blanking window is applied. If the blanking window is currently active, then the blanking window counter is restarted. |