ADC |
i2346 — ADC result has Error when switching
between odd and even channels |
YES |
NO |
ADC |
i2347 — VREF current consumption of ADC is
random at powerup |
YES |
NO |
ADC |
i2349 — ADC VrefHi Loading increase in
powerdown |
YES |
NO |
CONTROLSS |
i2352 — CONTROLSS-SDFM: Dynamically
Changing Threshold Settings (LLT, HLT), Filter Type, or COSR
Settings Will Trigger Spurious Comparator Events |
YES |
YES |
CONTROLSS |
i2353 — CONTROLSS-SDFM: Dynamically
Changing Data Filter Settings (Such as Filter Type or DOSR) Will
Trigger Spurious Data Acknowledge Events |
YES |
YES |
CONTROLSS |
i2354 — CONTROLSS-SDFM: Two Back-to-Back
Writes to SDCPARMx Register Bit Fields CEVT1SEL, CEVT2SEL, and HZEN
Within Three SD-Modulator Clock Cycles can Corrupt SDFM State
Machine, Resulting in Spurious Comparator Events |
YES |
YES |
CONTROLSS |
i2355 — CONTROLSS-ADC: DMA Read of Stale
Result |
YES |
YES |
CONTROLSS |
i2356 — CONTROLSS-ADC: Interrupts may Stop
if INTxCONT (Continue-to-Interrupt Mode) is not Set |
YES |
YES |
CONTROLSS |
i2357 — CONTROLSS-ePWM: An ePWM Glitch can
Occur if a Trip Remains Active at the End of the Blanking
Window |
YES |
YES |
CONTROLSS |
i2358 — CONTROLSS-ePWM: Trip Events Will
Not be Filtered by the Blanking Window for the First 3 Cycles After
the Start of a Blanking |
YES |
YES |
CONTROLSS |
i2359 — CONTROLSS-CMPSS:Prescaler counter behavior
different from spec when DACSOURCE is made 0 or reconfigured as
1 |
YES |
YES |
CONTROLSS |
i2405 — CONTROLSS: Race condition OUTPUT_XBAR and
PWM_XBAR resulting in event miss |
YES |
YES |
CPSW |
i2345 — CPSW: Ethernet Packet corruption
occurs if CPDMA fetches a packet which spans across memory
banks |
YES |
YES |
CPSW |
i2401 — CPSW: Host Timestamps Cause CPSW
Port to Lock up |
YES |
YES |
CPSW |
i2402 — CPSW: Ethernet to Host Checksum
Offload does not work |
YES |
YES |
CPSW |
i2438 — CPSW - Host to Ethernet Checksum Generation with VLAN
ADD/Remove |
YES |
YES |
CPSW |
i2439 — CPSW: Host to Ethernet Timestamp Accuracy Issue |
YES |
YES |
CRC |
i2386 — CRC: CRC 8-bit data width and
CRC8-SAE-J1850 and CRC8-H2F possible use in CAN module is not
supported |
YES |
YES |
DCC |
i2395 — DCC Module Frequency Comparison can
Report Erroneous Results |
YES |
YES |
GPMC |
i2313 — GPMC: Sub-32-bit read issue with
NAND and FPGA/FIFO |
YES |
YES |
M4 ROM |
i2403 — M4 ROM: SBL redundant boot image
feature not supported on HSSE devices |
NO |
YES |
MBOX |
i2404 — MBOX: Race condition in mailbox
registers resulting in events miss |
YES |
YES |
McSPI |
i2350 — McSPI data transfer using EDMA in
‘ABSYNC’ mode stops after 32 bits transfer |
YES |
YES |
MDIO |
i2329 — MDIO interface corruption (CPSW and
PRU-ICSS) |
YES |
NO |
PBIST |
i2374 — PBIST fails if clock frequency of
R5SS_CORE_CLK is not same as R5FSS_CLK_SELECTED frequency |
YES |
YES |
SOC CONTROL |
i2392 — Race condition in mem-init capture
registers resulting in events miss |
YES |
YES |
BUS SAFETY |
i2393 — Granular error status not logged in BUS_SAFETY_ERR registers
for the detected faults |
YES |
YES |
SOC CONTROL |
i2394 — Race condition in interrupt and
error aggregator capture registers resulting in events miss |
YES |
YES |
SFDM |
i2375 — SDFM module event flags
(SDIFLG.FLTx_FLG_CEVTx) do not get set again if the comparator event
is still active and digital filter path (using
SDCOMPxCTL.CEVTxDIGFILTSEL) is being selected |
YES |
YES |
UART |
i2310 — USART: Erroneous triggering of
timeout interrupt |
YES |
YES |
UART |
i2311 — USART: Spurious DMA
Interrupts |
YES |
YES |
RAM SEC |
i2427 — RAM SEC can cause Spurious RAM writes resulting in L2 &
MBOX memory corruption |
YES |
YES |
AES |
i2428 — AES in DTHE generates extra dma request for data_in at the end
of GCM encrypt |
YES |
YES |
ICSS |
i2433 — ICSS: Reading the 64-bit IEP timer does not have a lock MSW
logic when LSW is read |
YES |
YES |
CPSW |
i2438 — CPSW: Host to Ethernet Checksum Generation with VLAN
ADD/Remove |
YES |
YES |
CPSW |
i2439 — CPSW: Host to Ethernet Timestamp Accuracy Issue |
YES |
YES |