Two of the most frequently asked questions we receive from customers who are new to integrating TI DLP® Pico™ display technology are:
Brightness [1] is a seemingly simple specification. But how much brightness is required for a given pico projection application -- and the engineering tradeoffs involved in achieving higher brightness -- are more complex topics.
How bright a pico projection system needs to be for a given end equipment depends mainly on three factors:
The bigger the screen size and brighter the desired image, the more projection brightness is typically required. In addition, the ambient lighting environment can drastically impact the brightness required to achieve the desired screen size. Figure 1 suggests projector brightness levels and DLP chipsets when taking into account various screen sizes and ambient lighting environments that users might encounter when designing their products with DLP pico projection.
To address the question of how much brightness can be achieved, it is important to understand key variables that can be changed at a system design level, as illustrated in Table 1. To make a brighter LED projection solution, it is necessary to increase some of these variables:
Variable | Contribution | Limitation |
---|---|---|
LED size | Amount of light that can be generated | LED thermal limit |
Optics size | Amount of light that can be collected | Size and cost |
DLP chip size | Amount of light that can be reflected | Cost |
LED current | LED brightness level | LED thermal limit |
Thermal solution | Amount of heat dissipated from the LEDs | Size and thus cost |
To better understand these variables, we will explore an optical module.
TI sells a variety of DLP Pico chipsets to third party companies who in turn design and manufacture optical modules and make them available to product developers. These optical modules typically include a DMD, RGB LED illumination and optics. Different optical module models may have different brightness capabilities depending primarily on the combination of DMD size, LED size and optical throughput. A given optical module can also vary in brightness depending on the power applied to the LEDs.
If power is applied to the optical module’s LEDs -- and video content sent to the DLP controller chip -- the optical module projects an image. As illustrated in Figure 3, when power to LEDs is increased, brightness grows but at a declining rate; meanwhile, the heat emitted by the LEDs grows at an increasing rate.
TI recently published an application note exploring this topic in more detail, entitled TI DLP Pico System Design: Brightness Requirements and Tradeoffs. In addition, TI has created a downloadable brightness and throw ratio calculator tool. Both of these complementary resources can help developers and brands integrating DLP Pico technology in their products better understand the requirements and tradeoffs to optimize projection brightness.
[1] For the purposes of this blog post, brightness is defined as measured brightness, or the actual light output of a projector.
TI PROVIDES TECHNICAL AND RELIABILITY DATA (INCLUDING DATASHEETS), DESIGN RESOURCES (INCLUDING REFERENCE DESIGNS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, SAFETY INFORMATION, AND OTHER RESOURCES “AS IS” AND WITH ALL FAULTS, AND DISCLAIMS ALL WARRANTIES, EXPRESS AND IMPLIED, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF THIRD PARTY INTELLECTUAL PROPERTY RIGHTS.
These resources are intended for skilled developers designing with TI products. You are solely responsible for (1) selecting the appropriate TI products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, or other requirements. These resources are subject to change without notice. TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource. Other reproduction and display of these resources is prohibited. No license is granted to any other TI intellectual property right or to any third party intellectual property right. TI disclaims responsibility for, and you will fully indemnify TI and its representatives against, any claims, damages, costs, losses, and liabilities arising out of your use of these resources.
TI’s products are provided subject to TI’s Terms of Sale (www.ti.com/legal/termsofsale.html) or other applicable terms available either on ti.com or provided in conjunction with such TI products. TI’s provision of these resources does not expand or otherwise alter TI’s applicable warranties or warranty disclaimers for TI products.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2023, Texas Instruments Incorporated