SWRA513C January 2020 – September 2020 CC3120 , CC3120MOD , CC3135 , CC3135MOD , CC3220MOD , CC3220MODA , CC3220R , CC3220S , CC3220SF , CC3235MODS , CC3235MODSF , CC3235S , CC3235SF
When the provisioning process starts in APSC plus external configuration mode, the device is ready to serve stations that are:
Unlike other configuration modes, this mode lets the host send commands and receive events from the networking subsystem while provisioning is running. The APIs are unblocked when the EXTERNAL_CONFIGURATION_READY event is sent to the host. The event is sent immediately after the networking subsystem successfully starts the provisioning process.
When the host identifies that the user chooses to use the external configuration method, it should stop the internal running provisioning process, and continue carrying out the external provisioning process.
If the user chooses to use one of the internal provisioning methods (AP or SC provisioning), the device must be restarted before it can continue with the internal provisioning process. At this point, the networking subsystem sends a RESET_REQUEST event to the host. The host should stop its external provisioning process (close opened sockets and so forth), restart the SimpleLink Wi-Fi device, and wait for the internal provisioning process to end as usual.