SWRA681 September 2020 CC3100 , CC3100MOD , CC3120 , CC3120MOD , CC3135 , CC3135MOD , CC3200 , CC3200MOD , CC3220MOD , CC3220MODA , CC3220R , CC3220S , CC3220SF , CC3235MODAS , CC3235MODASF , CC3235MODS , CC3235MODSF , CC3235S , CC3235SF
The test procedure for configuring the Wi-Fi devices (CC3x20 and CC3x35) by using the Radio Testing Tool [9] and for compliance testing against EN 301 489 [5] standard is described in the following sub sections. The same test procedure applies to CC3100 and CC3200 devices, but need to use the CC3100-CC3200 Radio Testing Tool [12] to configure and test the devices. The EMC Emission requirements for the relevant ports of radio and ancillary equipment and their applicability are shown in the Emission Requirements table in CE Regulations for SRDs Operating in License-Free 2.4 GHz/5 GHz Bands [1] and the immunity requirements for the relevant ports of radio and ancillary equipment and their applicability are shown in the Immunity Requirements table of CE Regulations for SRDs Operating in License-Free 2.4 GHz/5 GHz Bands [1].