Table 2-1 lists the key system specifications of this design.
Parameter | Conditions | Spec Range | Unit | ||
---|---|---|---|---|---|
Minimum | Typical | Maximum | |||
Cell architecture | BQ76942 | 3 | 10 | Series | |
BQ769142 | 3 | 14 | Series | ||
BQ76952 | 3 | 16 | Series | ||
Cell balancing peak current | Cell voltage: 4000 mV | 117 | mA | ||
Charge current | 27 | A | |||
Discharge current | 27 | A | |||
Pre-discharge current | Pack voltage: 48 V | 160 | mA | ||
Cell Voltage accuracy | 25°C | ±5 | mV | ||
0°C–60°C | ±10 | mV | |||
Pack current accuracy | < 2 A | ±10 | mA | ||
> 2 A | ±0.5 | % | |||
Primary OV protection | Threshold | 4200 | mV | ||
Delay | 2 | s | |||
Secondary OV protection | Threshold | 4325 | mV | ||
Delay | 1 | s | |||
Primary UV protection | Threshold | 2530 | mV | ||
Delay | 2 | s | |||
Secondary UV protection | Threshold | 2250 | mV | ||
Delay | 1 | s | |||
OCD protection - level 1 | Threshold | 10 | A | ||
Delay | 425 | ms | |||
OCD protection - level 2 | Threshold | 30 | A | ||
Delay | 56 | ms | |||
OCC protection | Threshold | 10 | A | ||
Delay | 425 | ms | |||
SCD protection | Threshold | 200 | A | ||
Delay | 300 | µs | |||
Over temperature protection | Charge | 55 | °C | ||
Discharge | 60 | °C | |||
Under temperature protection | Charge | 0 | °C | ||
Discharge | –20 | °C | |||
Maximum pack+ voltage | Charge MOSFET off | 120 | V | ||
Standby mode current consumption | 100 | µA | |||
Ship mode current consumption | 10 | µA |