SLLSF04D
April 2018 – June 2022
TLIN1024-Q1
PRODUCTION DATA
1
Features
2
Applications
3
Description
4
Revision History
5
Pin Configuration and Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
ESD Ratings
6.3
ESD Ratings - IEC
6.4
Thermal Information
6.5
Recommended Operating Conditions
6.6
Electrical Characteristics
6.7
Switching Characteristics (1)
6.8
Timing Requirements
Typical Characteristics
Parameter Measurement Information
7
Detailed Description
7.1
Overview
7.2
Functional Block Diagram
7.3
Feature Description
7.3.1
LIN (Local Interconnect Network) Bus
7.3.1.1
LIN Transmitter Characteristics
7.3.1.2
LIN Receiver Characteristics
7.3.1.2.1
Termination
7.3.2
TXD (Transmit Input/Output)
7.3.3
RXD (Receive Output)
7.3.4
VSUP1/2 (Supply Voltage)
7.3.5
GND (Ground)
7.3.6
EN (Enable Input)
7.3.7
Protection Features
7.3.8
TXD Dominant Time Out (DTO)
7.3.9
Bus Stuck Dominant System Fault: False Wake Up Lockout
7.3.10
Thermal Shutdown
7.3.11
Under Voltage on VSUP
7.3.12
Unpowered Device and LIN Bus
7.4
Device Functional Modes
7.4.1
Normal Mode
7.4.2
Sleep Mode
7.4.3
Standby Mode
7.4.4
Wake Up Events
7.4.4.1
Wake Up Request (RXD)
7.4.4.2
Mode Transitions
8
Application and Implementation
8.1
Application Information
8.2
Typical Application
8.2.1
Design Requirements
8.2.2
Detailed Design Procedure
8.2.2.1
Normal Mode Application Note
8.2.2.2
Standby Mode Application Note
8.2.2.3
TXD Dominant State Timeout Application Note
8.2.3
Application Curves
8.3
Power Supply Recommendations
8.4
Layout
8.4.1
Layout Guidelines
8.4.2
Layout Example
9
Device and Documentation Support
9.1
Documentation Support
9.1.1
Related Documentation
9.2
Receiving Notification of Documentation Updates
9.3
Support Resources
9.4
Trademarks
9.5
Electrostatic Discharge Caution
9.6
Glossary
10
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
RGY|24
MPQF143E
Thermal pad, mechanical data (Package|Pins)
RGY|24
QFND581
Orderable Information
sllsf04d_oa
sllsf04d_pm
1
Features
AEC Q100 Qualified for automotive applications
Temperature: –40 to 125°C ambient
HBM Classification level: ±8 kV
CDM Classification level: ±1.5 kV
Compliant to LIN2.0, LIN2.1, LIN2.2, LIN2.2A and ISO/DIS 17987–4.2 (See
SLLA492
)
Conforms to SAE J2602 recommended practice for LIN (See
SLLA492
)
Supports 12 V battery applications
LIN transmit data rate up to 20 kbps
Wide operating ranges
4 V to 36 V supply voltage
±45 V LIN bus fault protection
Sleep mode: ultra-low current consumption
allows wake up event from:
LIN bus
Local wake up through EN
Power up and down glitch free operation
Protection features:
Under voltage protection on V
SUP
TXD Dominant time out protection (DTO)
Thermal shutdown protection
Unpowered node or ground disconnection
failsafe at system level.
3.5 mm × 5.5 mm QFN package with improved