Startseite Verstärker Verstärker für Spezialfunktionen Logarithmische Verstärker

LOG200

VORSCHAU

Logarithmischer Hochgeschwindigkeits-Präzisionsverstärker mit Photodiodenvorspannung und Dunkelst

Produktdetails

Input current range (min) (nA) 0.1 Input current range (max) (mA) 10 Offset voltage (input amplifiers) (max) (mV) 2000 Vs (±) (min) (V) 4.5 Vs (±) (max) (V) 12.6 Iq (max) (mA) 9 Dynamic range (typ) (dB) 160 Reference type Int Auxiliary op amps 1 Full-scale output voltage (min) (±V) 4.8 Full-scale output voltage (max) (±V) 12.3 Conformity error (initial 5 decades) (max) (%) 1.5 Conformity error (initial 5 decades) (typ. over temp) (%/°C) 0.2 Operating temperature range (°C) -40 to 125 Rating Catalog
Input current range (min) (nA) 0.1 Input current range (max) (mA) 10 Offset voltage (input amplifiers) (max) (mV) 2000 Vs (±) (min) (V) 4.5 Vs (±) (max) (V) 12.6 Iq (max) (mA) 9 Dynamic range (typ) (dB) 160 Reference type Int Auxiliary op amps 1 Full-scale output voltage (min) (±V) 4.8 Full-scale output voltage (max) (±V) 12.3 Conformity error (initial 5 decades) (max) (%) 1.5 Conformity error (initial 5 decades) (typ. over temp) (%/°C) 0.2 Operating temperature range (°C) -40 to 125 Rating Catalog
VQFN (RGT) 16 9 mm² 3 x 3
  • Ultra-fast transient response to low current levels:
    • Settling time for 10‑nA to 100‑nA step: 220‑ns rising, 630‑ns falling (typ)
    • Settling time for 100‑nA to 1‑µA step: 80‑ns rising, 240‑ns falling (typ)
  • Wide dynamic current range: 100 pA to 10 mA (160 dB)
  • High signal bandwidth:
    • 6 MHz at 1 µA to 10 mA
    • 120 kHz at 1 nA
  • High-accuracy transfer function:
    • 0.2 % max log conformity error
  • Integrated reference current (1 µA) and reference voltages (2.5 V and 1.65 V) for accurate ratio calculation
  • Low reference drift: 20 ppm/°C (typ)
  • Additional auxiliary high-speed op amp for differential ADC drive, single-ended gain or filter blocks, and other peripheral functions
  • Single supply (4.5 V to 12.6 V) or dual supply (±2.25 V to ±6.3 V) operation
  • Low quiescent current: 9.5 mA
  • Specified temperature range: –40°C to +125°C
  • Small package: 3 mm × 3 mm VQFN
  • Ultra-fast transient response to low current levels:
    • Settling time for 10‑nA to 100‑nA step: 220‑ns rising, 630‑ns falling (typ)
    • Settling time for 100‑nA to 1‑µA step: 80‑ns rising, 240‑ns falling (typ)
  • Wide dynamic current range: 100 pA to 10 mA (160 dB)
  • High signal bandwidth:
    • 6 MHz at 1 µA to 10 mA
    • 120 kHz at 1 nA
  • High-accuracy transfer function:
    • 0.2 % max log conformity error
  • Integrated reference current (1 µA) and reference voltages (2.5 V and 1.65 V) for accurate ratio calculation
  • Low reference drift: 20 ppm/°C (typ)
  • Additional auxiliary high-speed op amp for differential ADC drive, single-ended gain or filter blocks, and other peripheral functions
  • Single supply (4.5 V to 12.6 V) or dual supply (±2.25 V to ±6.3 V) operation
  • Low quiescent current: 9.5 mA
  • Specified temperature range: –40°C to +125°C
  • Small package: 3 mm × 3 mm VQFN

The LOG200 is a wide-dynamic-range current-to-voltage amplifier specifically designed to optimize current measurements across 160 dB of dynamic range with unparalleled accuracy and speed for optical communications, medical diagnostics, and industrial process control measurements. The LOG200 features two logarithmic amplifiers followed by a high-accuracy differential amplifier that convert current signals into a voltage representing the log-compressed ratio of the two currents. The current inputs are designed to feature a high-speed response from one input, and a highly accurate reference signal on the other input, allowing for a unique combination of fast transient response and high logarithmic conformity.

The LOG200 ratio is internally set to 250 mV/decade of current-to-voltage conversion. The device integrates an uncommitted high-speed amplifier to allow the output to be configured for differential or filtered responses, with a fast settling time to drive successive approximation analog-to-digital converters (SAR ADCs). The LOG200 also features a separate reference current and reference voltage designed to configure the device for optimized input current and common-mode voltages.

The LOG200 can be powered in a single-supply (4.5 V to 12.6 V) or dual-supply (±2.25 V to ±6.3 V) configuration and is specified from –40°C to +125°C.

The LOG200 is a wide-dynamic-range current-to-voltage amplifier specifically designed to optimize current measurements across 160 dB of dynamic range with unparalleled accuracy and speed for optical communications, medical diagnostics, and industrial process control measurements. The LOG200 features two logarithmic amplifiers followed by a high-accuracy differential amplifier that convert current signals into a voltage representing the log-compressed ratio of the two currents. The current inputs are designed to feature a high-speed response from one input, and a highly accurate reference signal on the other input, allowing for a unique combination of fast transient response and high logarithmic conformity.

The LOG200 ratio is internally set to 250 mV/decade of current-to-voltage conversion. The device integrates an uncommitted high-speed amplifier to allow the output to be configured for differential or filtered responses, with a fast settling time to drive successive approximation analog-to-digital converters (SAR ADCs). The LOG200 also features a separate reference current and reference voltage designed to configure the device for optimized input current and common-mode voltages.

The LOG200 can be powered in a single-supply (4.5 V to 12.6 V) or dual-supply (±2.25 V to ±6.3 V) configuration and is specified from –40°C to +125°C.

Herunterladen Video mit Transkript ansehen Video

Technische Dokumentation

star =Von TI ausgewählte Top-Empfehlungen für dieses Produkt
Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 3
Typ Titel Datum
* Data sheet LOG200 Precision, High-Speed Logarithmic Amplifier With Integrated Photodiode Bias datasheet PDF | HTML 14 Aug 2023
EVM User's guide LOG200 Evaluation Module User's Guide (Rev. A) PDF | HTML 22 Jan 2024
Certificate LOG200EVM EU Declaration of Conformity (DoC) 30 Jun 2023

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Evaluierungsplatine

LOG200EVM — LOG200 Evaluierungsmodul

Das Evaluierungsmodul (EVM) LOG200 ist eine Entwicklungsplattform zur Evaluierung des LOG200, eines logarithmischen Präzisionsverstärkers mit hoher Geschwindigkeit und integrierter Fotodiodenvorspannung sowie Dunkelstromkorrektur. LOG200 ist für Strommessungen über einen Dynamikbereich von 160 dB (...)

Benutzerhandbuch: PDF | HTML
Simulationsmodell

LOG200 PSpice Model

SBOMCF1.ZIP (97 KB) - PSpice Model
Simulationsmodell

LOG200 TINA-TI Reference Design

SBOMCF2.TSC (93 KB) - TINA-TI Reference Design
Simulationsmodell

LOG200 TINA-TI SPICE Model

SBOMCF0.ZIP (38 KB) - TINA-TI Spice Model
Simulationstool

PSPICE-FOR-TI — PSpice® für TI Design-und Simulationstool

PSpice® für TI ist eine Design- und Simulationsumgebung, welche Sie dabei unterstützt, die Funktionalität analoger Schaltungen zu evaluieren. Diese voll ausgestattete Design- und Simulationssuite verwendet eine analoge Analyse-Engine von Cadence®. PSpice für TI ist kostenlos erhältlich und (...)
Simulationstool

TINA-TI — SPICE-basiertes analoges Simulationsprogramm

TINA-TI provides all the conventional DC, transient and frequency domain analysis of SPICE and much more. TINA has extensive post-processing capability that allows you to format results the way you want them. Virtual instruments allow you to select input waveforms and probe circuit nodes voltages (...)
Benutzerhandbuch: PDF
Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
VQFN (RGT) 16 Ultra Librarian

Bestellen & Qualität

Beinhaltete Information:
  • RoHS
  • REACH
  • Bausteinkennzeichnung
  • Blei-Finish/Ball-Material
  • MSL-Rating / Spitzenrückfluss
  • MTBF-/FIT-Schätzungen
  • Materialinhalt
  • Qualifikationszusammenfassung
  • Kontinuierliches Zuverlässigkeitsmonitoring
Beinhaltete Information:
  • Werksstandort
  • Montagestandort

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videos