Detalles del producto

Package name DSBGA, WSON Peak pulse power (8/20 μs) (max) (W) 1330 IEC 61000-4-5 (kA) 0.035 Vrwm (V) 33 Breakdown voltage (min) (V) 34 Bi-/uni-directional Uni-Directional Number of channels 1 IO capacitance (typ) (pF) 130 Clamping voltage (V) 38
Package name DSBGA, WSON Peak pulse power (8/20 μs) (max) (W) 1330 IEC 61000-4-5 (kA) 0.035 Vrwm (V) 33 Breakdown voltage (min) (V) 34 Bi-/uni-directional Uni-Directional Number of channels 1 IO capacitance (typ) (pF) 130 Clamping voltage (V) 38
DSBGA (YZF) 4 1.185192 mm² 1.062 x 1.116 WSON (DRV) 6 4 mm² 2 x 2
  • Protection Against 1 kV, 42 Ω IEC 61000-4-5 Surge Test for Industrial Signal Lines
  • Max Clamping Voltage of 40 V at 35 A of 8/20 µs Surge Current
  • Standoff Voltage: 33 V
  • Tiny 1.1 mm2 WCSP and 4 mm2 SON Footprints
  • Survives Over 4,000 Repetitive Strikes of 30 A 8/20 µs Surge Current at 125°C
  • Robust Surge Protection
    • IEC61000-4-5 (8/20 µs): 35 A
    • IEC61643-321 (10/1000 µs): 4 A
  • Low Leakage Current
    • 19 nA Typical at 27°C
    • 28 nA Typical at 85°C
  • Low Capacitance: 130 pF
  • Integrated Level 4 IEC 61000-4-2 ESD Protection
  • Protection Against 1 kV, 42 Ω IEC 61000-4-5 Surge Test for Industrial Signal Lines
  • Max Clamping Voltage of 40 V at 35 A of 8/20 µs Surge Current
  • Standoff Voltage: 33 V
  • Tiny 1.1 mm2 WCSP and 4 mm2 SON Footprints
  • Survives Over 4,000 Repetitive Strikes of 30 A 8/20 µs Surge Current at 125°C
  • Robust Surge Protection
    • IEC61000-4-5 (8/20 µs): 35 A
    • IEC61643-321 (10/1000 µs): 4 A
  • Low Leakage Current
    • 19 nA Typical at 27°C
    • 28 nA Typical at 85°C
  • Low Capacitance: 130 pF
  • Integrated Level 4 IEC 61000-4-2 ESD Protection

The TVS3300 robustly shunts up to 35 A of IEC 61000-4-5 fault current to protect systems from high power transients or lightning strikes. The device offers a solution to the common industrial signal line EMC requirement to survive up to 1 kV IEC 61000-4-5 open circuit voltage coupled through a 42 Ω impedance. The TVS3300 uses a unique feedback mechanism to ensure precise flat clamping during a fault, assuring system exposure below 40 V. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness.

In addition, the TVS3300 is available in small 1 mm × 1.1 mm WCSP and 2 mm × 2 mm SON footprints which are ideal for space constrained applications, offering up to a 90 percent reduction in size compared to industry standard SMA and SMB packages. The extremely low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS3300 against 4000 repetitive surge strikes at high temperature with no shift in device performance.

The TVS3300 is part of TI’s Flat-Clamp family of surge devices. For more information on the other devices in the family, see the Device Comparison Table

The TVS3300 robustly shunts up to 35 A of IEC 61000-4-5 fault current to protect systems from high power transients or lightning strikes. The device offers a solution to the common industrial signal line EMC requirement to survive up to 1 kV IEC 61000-4-5 open circuit voltage coupled through a 42 Ω impedance. The TVS3300 uses a unique feedback mechanism to ensure precise flat clamping during a fault, assuring system exposure below 40 V. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness.

In addition, the TVS3300 is available in small 1 mm × 1.1 mm WCSP and 2 mm × 2 mm SON footprints which are ideal for space constrained applications, offering up to a 90 percent reduction in size compared to industry standard SMA and SMB packages. The extremely low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS3300 against 4000 repetitive surge strikes at high temperature with no shift in device performance.

The TVS3300 is part of TI’s Flat-Clamp family of surge devices. For more information on the other devices in the family, see the Device Comparison Table

Descargar Ver vídeo con transcripción Video

Documentación técnica

star =Principal documentación para este producto seleccionada por TI
No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
Ver todo 17
Tipo Título Fecha
* Data sheet TVS3300 33-V Flat-Clamp Surge Protection Device datasheet (Rev. C) PDF | HTML 14 feb 2018
Selection guide System-Level ESD Protection Guide (Rev. D) 07 sep 2022
Application brief Protecting I/O modules from surge events 04 feb 2019
Application brief TVS Surge Rating: Power vs. Current 12 nov 2018
White paper Demystifying surge protection 06 nov 2018
User guide Flat Clamp TVS Evaluation Module—Adaptor Boards 10 sep 2018
Application note How to select a Surge Diode 29 ago 2018
Technical article These are not your grandfather’s TVS diodes PDF | HTML 05 abr 2018
Application brief Flat-Clamp TVS Layout in SMA/SMB Footprints 03 abr 2018
Application note TVS Surge Protection in High-Temperature Environments 23 mar 2018
User guide TVS0500-3300 Evaluation Module—Adaptor Boards User's Guide (Rev. B) 08 mar 2018
White paper Flat-Clamp surge protection technology for efficient system protection 15 ene 2018
Technical article Protecting field transmitters from surge transients PDF | HTML 08 sep 2017
Application note TVS3300 Bidirectional Characterization 22 mar 2017
User guide TVS3300YZF 33-V Precision Surge Protection Clamp Evaluation Module User's Guide 25 ene 2017
User guide TVS3300 Evaluation Module—Bidirectional Adaptor Board User's Guide 10 ene 2017
User guide TVS3300DRV 33-V Precision Surge Protection Clamp Evaluation Module User's Guide 09 ene 2017

Diseño y desarrollo

Para conocer los términos adicionales o los recursos necesarios, haga clic en cualquier título de abajo para ver la página de detalles cuando esté disponible.

Placa de evaluación

FLAT-CLAMP-TVS-EVM — Módulo de evaluación TVSxx0x de diodos de protección contra sobretensiones de precisión

The FLAT-CLAMP-TVS-EVM (Precision Surge Protection Diode Adaptor Board Evaluation Module) demonstrates the characteristics, operation, and use of the TVSxx0x family of devices. The TVSxx0x family of devices are precision clamps that keep ultra-low and flat clamping voltages during transient (...)
Guía del usuario: PDF
Modelo de simulación

TVS3300 IBIS Model

SLVMC41.ZIP (4 KB) - IBIS Model
Modelo de simulación

TVS3300 PSpice Transient Model

SLVMCA0.ZIP (65 KB) - PSpice Model
Modelo de simulación

TVS3300 TINA-TI Transient Reference Design

SLVMCA9.TSC (3355 KB) - TINA-TI Reference Design
Modelo de simulación

TVS3300 TINA-TI Transient Spice Model

SLVMCB0.ZIP (11 KB) - TINA-TI Spice Model

Muchos diseños de referencia de TI incluyen TVS3300

Utilice nuestra herramienta de selección de diseños de referencia para revisar e identificar los diseños que mejor se adaptan a su aplicación y parámetros.

Encapsulado Pines Símbolos CAD, huellas y modelos 3D
DSBGA (YZF) 4 Ultra Librarian
WSON (DRV) 6 Ultra Librarian

Pedidos y calidad

Información incluida:
  • RoHS
  • REACH
  • Marcado del dispositivo
  • Acabado de plomo/material de la bola
  • Clasificación de nivel de sensibilidad a la humedad (MSL) / reflujo máximo
  • Estimaciones de tiempo medio entre fallas (MTBF)/fallas en el tiempo (FIT)
  • Contenido del material
  • Resumen de calificaciones
  • Monitoreo continuo de confiabilidad
Información incluida:
  • Lugar de fabricación
  • Lugar de ensamblaje

Los productos recomendados pueden tener parámetros, módulos de evaluación o diseños de referencia relacionados con este producto de TI.

Soporte y capacitación

Foros de TI E2E™ con asistencia técnica de los ingenieros de TI

El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.

Si tiene preguntas sobre la calidad, el paquete o el pedido de productos de TI, consulte el soporte de TI. ​​​​​​​​​​​​​​

Videos