SBAS661C February 2015 – May 2021 ADS1262 , ADS1263
PRODUCTION DATA
After the power supplies are turned on, the ADC remains in reset until VDVDD, the internal LDO output (BYPASS pin voltage), and the combined (VAVDD – VAVSS) power supply voltage have exceeded their respective POR voltage thresholds. Figure 9-52 shows the POR sequence. When the power supplies have crossed the voltage thresholds, the ADC is operational 65536 fCLK cycles later (9 ms, typical). Note the 1-µF capacitor connected to the BYPASS pin requires charging at power-on, and as a result, can delay when the ADC is operational. Wait at least 9 ms after the power supplies have fully stabilized before beginning ADC communication.
PARAMETER | TEST CONDITIONS | TYP | UNIT | |
---|---|---|---|---|
VDIGITAL_POR | Digital power supply POR threshold | VDVDD and VBYPASS | 1 | V |
VANALOG_POR | Analog power supply POR threshold | VAVDD – VAVSS | 3.5 | V |
td(POROP) | Propagation delay from last POR supply threshold to ADC operational | 65536 | tCLK(1) |