SNVSBY2A January   2021  – June 2021 UCC12051-Q1

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Power Ratings
    6. 6.6  Insulation Specifications
    7. 6.7  Safety-Related Certifications
    8. 6.8  Safety Limiting Values
    9. 6.9  Electrical Characteristics
    10. 6.10 Switching Characteristics
    11. 6.11 Insulation Characteristics Curves
    12. 6.12 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Enable and Disable
      2. 7.3.2 UVLO, Power-Up, and Power-Down Behavior
      3. 7.3.3 VISO Load Recommended Operating Area
      4. 7.3.4 Thermal Shutdown
      5. 7.3.5 External Clocking and Synchronization
      6. 7.3.6 VISO Output Voltage Selection
      7. 7.3.7 Electromagnetic Compatibility (EMC) Considerations
    4. 7.4 Device Functional Modes
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 VISO Output Capacitor Selection
      3. 8.2.3 Application Curves
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Example
  11. 11Device and Documentation Support
    1. 11.1 Device Support
      1. 11.1.1 Development Support
    2. 11.2 Documentation Support
      1. 11.2.1 Related Documentation
    3. 11.3 Receiving Notification of Documentation Updates
    4. 11.4 Support Resources
    5. 11.5 Trademarks
    6. 11.6 Electrostatic Discharge Caution
    7. 11.7 Glossary
  12. 12Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Electrical Characteristics

Over operating temperature range (TJ = –40°C to 150°C), VINP = 4.5V to 5.5V, CINP = COUT = 10 µF, internal clock mode, unless otherwise noted. All typical values at TA = 25°C and VINP = 5.0V.
PARAMETERTEST CONDITIONSMINTYPMAXUNIT
INPUT SUPPLY
IVINQVINP quiescent current,disabledEN=LOW100uA
IVINOVINP operating current, no loadEN=HI; SEL shorted to VISO (5.0V output)52

80

mA
EN=HI; SEL 100kΩ to VISO (5.4V output)4870
EN=HI; SEL shorted to GNDS (3.3V output)96

140

EN=HI; SEL 100kΩ to GNDS (3.7V output)82120
IVIN_SCDC current from VINP supplyunder short circuit on VISOVISO short to GNDS245mA
VUVPRVINP under-voltage lockout rising threshold4.25

4.45

V
VUVPFVINP under-voltage lockout falling threshold

3.5

3.75V
VUVPHVINP under-voltage lockout hysteresis0.5V
EN, SYNC INPUT PINS
VIRInput voltage threshold, logic HIGHRising edge2.2V
VIFInput voltage threshold, logic LOWFalling edge0.8V
IENEnable Pin Input CurrentVEN = 5.0 V510uA
ISYNCSYNC Pin Input CurrentVSYNC = 5.0 V0.021uA
SYNC_OK PIN
VOLSYNC_OK output low voltageISYNC_OK = - 2 mA0.15V
ILKG_SYNC_OKSYNC_OK pin leakage currentVSYNC_OK = 5.0 V1uA
DC/DC CONVERTER
VISOIsolated supply output voltageSEL shorted to VISO (5.0V output); IISO = 55 mA (3)

4.8

5

5.2

V
SEL 100kΩ to VISO (5.4 V output); IISO = 45 mA (3)

5.18

5.4

5.62

V
SEL shorted to GNDS (3.3V output); IISO = 100 mA (3)

3.17

3.3

3.43

V
SEL 100kΩ to GNDS (3.7 V output); IISO = 90 mA (3)

3.55

3.7

3.85

V
VISO(RIP)Voltage ripple on isolated supply output (pk-pk)(1)20-MHz bandwidth, CLOAD = 10 uF || 0.1 uF, SEL shorted to VISO (5.0V output); IISO = 100 mA50mV
20-MHz bandwidth, CLOAD = 10 uF || 0.1 uF, SEL 100kΩ to VISO (5.4V output); IISO = 90 mA50mV
20-MHz bandwidth, CLOAD = 10 uF || 0.1 uF, SEL shorted to GNDS (3.3V output); IISO = 145 mA50mV
20-MHz bandwidth, CLOAD = 10 uF || 0.1 uF, SEL shorted to GNDS (3.7V output); IISO = 130 mA50mV
VISO(LINE)VISO DC line regulationSEL shorted to VISO (5.0 V output); IISO = 55 mA, VINP = 4.5 V to 5.5 V1%
SEL shorted to GNDS (3.3 V output); IISO = 100 mA, VINP = 4.5 V to 5.5 V1%
VISO(LOAD)VISO DC load regulationSEL shorted to VISO (5.0 V output); IISO = 0 to 100 mA1.5%
SEL shorted to GNDS (3.3 V output); IISO = 0 to 145 mA1.5%
EFFEfficiency at maximum recommended load (2)SEL shorted to VISO (5.0 V output); IISO = 100 mA60%
SEL 100kΩ to VISO (5.4V output); IISO = 90 mA60%
SEL shorted to GNDS (3.3V output); IISO = 145 mA50%
SEL 100kΩ to GNDS (3.7V output); IISO = 130 mA53%
tRISEVISO rise time, 10% - 90%EN = change from LO to HI, SEL shorted to VISO (5.0V output); IISO = 1 mA750

1000

µs
EN = change from LO to HI, SEL 100kΩ to GNDS (3.3V output); IISO = 1 mA300

500

µs
THERMAL SHUTDOWN
TSDTHRThermal shutdown threshold(1) Junction Temperature, Rising165°C
TSDHYSTThermal shutdown hysteresis(1) Junction Temperature, Falling27°C
Not tested in production. Ensured by characterization.
Efficiency calculation: EFF = (VISO × IISO) / (VINP × IINP)
See the VISO Load Recommended Oeprating Area section for discussion of VISO regulation across load and temperature conditions for all output voltage settings.