JAJSGV8B September   2019  – December 2019 DRV8904-Q1 , DRV8906-Q1 , DRV8908-Q1 , DRV8910-Q1 , DRV8912-Q1

UNLESS OTHERWISE NOTED, this document contains PRODUCTION DATA.  

  1. 特長
  2. アプリケーション
  3. 概要
    1.     概略回路図
  4. 改訂履歴
  5. Device Comparison Table
  6. Pin Configuration and Functions
    1.     Pin Functions—DRV8912-Q1
    2.     Pin Functions—DRV8910-Q1
    3.     Pin Functions—DRV8908-Q1
    4.     Pin Functions—DRV8906-Q1
    5.     Pin Functions—DRV8904-Q1
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Timing Requirements
    7. 7.7 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Half Bridge Drivers
        1. 8.3.1.1 Control Modes
          1. 8.3.1.1.1 Continuous Mode (Without PWM)
          2. 8.3.1.1.2 Chopping Mode (With PWM)
            1. 8.3.1.1.2.1 PWM Configuration
            2. 8.3.1.1.2.2 Free-Wheeling Mode (Synchronous Rectification) Disable / Enable
            3. 8.3.1.1.2.3 PWM Channels Mapping
            4. 8.3.1.1.2.4 PWM Channels Configuration (PWM Frequency and PWM Duty)
            5. 8.3.1.1.2.5 Half-Bridge Enable
          3. 8.3.1.1.3 Parallel Mode (Continuous Operation)
          4. 8.3.1.1.4 Parallel Mode (PWM Operation)
            1. 8.3.1.1.4.1 PWM Configuration
            2. 8.3.1.1.4.2 Free-Wheeling Mode (Synchronous Rectification) Disable / Enable
            3. 8.3.1.1.4.3 PWM Channels Mapping
            4. 8.3.1.1.4.4 PWM Channels Configuration (PWM Frequency and PWM Duty)
            5. 8.3.1.1.4.5 PWM Generators Disable
            6. 8.3.1.1.4.6 Half-Bridge Enable
            7. 8.3.1.1.4.7 PWM Generators Enable
        2. 8.3.1.2 Half-Bridge Drive Architecture
          1. 8.3.1.2.1 Slew Rate
          2. 8.3.1.2.2 Cross Conduction (Dead Time)
          3. 8.3.1.2.3 Propagation Delay
      2. 8.3.2 Pin Diagrams
        1. 8.3.2.1 Logic Level Input Pin (nSLEEP, SCLK and SDI)
        2. 8.3.2.2 Logic Level Input Pin (nSCS)
        3. 8.3.2.3 Open Drain Output Pin (nFAULT)
        4. 8.3.2.4 Push Pull Output Pin (SDO)
      3. 8.3.3 Protection Circuits
        1. 8.3.3.1 VM Supply Undervoltage Lockout (UVLO)
        2. 8.3.3.2 VM Supply Overvoltage Protection (OVP)
        3. 8.3.3.3 Logic Supply Power on Reset (POR)
        4. 8.3.3.4 Overcurrent Protection (OCP)
        5. 8.3.3.5 Open-load detection (OLD)
          1. 8.3.3.5.1 Active OLD
            1. 8.3.3.5.1.1 Negative-current OLD
          2. 8.3.3.5.2 Low-current OLD
          3. 8.3.3.5.3 Passive OLD
        6. 8.3.3.6 Thermal Warning (OTW)
        7. 8.3.3.7 Thermal Shutdown (OTSD)
    4. 8.4 Device Functional Modes
      1. 8.4.1 Sleep Mode (nSLEEP = 0)
      2. 8.4.2 Operating Mode (nSLEEP = 1)
      3. 8.4.3 Fault Mode
    5. 8.5 Programming
      1. 8.5.1 SPI
      2. 8.5.2 SPI Format
      3. 8.5.3 SPI Interface for Multiple Slaves
        1. 8.5.3.1 SPI Interface for Multiple Slaves in Daisy Chain
    6. 8.6 Register Map
      1. 8.6.1 DRV8912-Q1 and DRV8910-Q1 Register Maps
        1. 8.6.1.1 Status Registers
          1. 8.6.1.1.1 IC Status (IC_STAT) Register (Address = 0x00) [reset = 0x00]
            1. Table 20. IC Status Register Field Descriptions
          2. 8.6.1.1.2 Overcurrent Protection (OCP) Status 1 (OCP_STAT_1) Register (Address = 0x01) [reset = 0x00]
            1. Table 21. Overcurrent Protection (OCP) Status 1 Register Field Descriptions
          3. 8.6.1.1.3 Overcurrent Protection (OCP) Status 2 (OCP_STAT_2) Register (Address = 0x02) [reset = 0x00]
            1. Table 22. Overcurrent Protection (OCP) Status 2 Register Field Descriptions
          4. 8.6.1.1.4 Overcurrent Protection (OCP) Status 3 (OCP_STAT_3) Register (Address = 0x03) [reset = 0x00]
            1. Table 23. Overcurrent Protection (OCP) Status 3 Register Field Descriptions
          5. 8.6.1.1.5 Open-Load Detect (OLD) Status 1 (OLD_STAT_1) Register (Address = 0x04) [reset = 0x00]
            1. Table 24. Open-Load Detect (OLD) Status 1 Register Field Descriptions
          6. 8.6.1.1.6 Open-Load Detect (OLD) Status 2 (OLD_STAT_2) Register (Address = 0x05) [reset = 0x00]
            1. Table 25. Open-Load Detect (OLD) Status 2 Register Field Descriptions
          7. 8.6.1.1.7 Open-Load Detect (OLD) Status 3 (OLD_STAT_3) Register (Address = 0x06) [reset = 0x00]
            1. Table 26. Open-Load Detect (OLD) Status 3 Register Field Descriptions
        2. 8.6.1.2 Control Registers
          1. 8.6.1.2.1  Configuration (CONFIG_CTRL) Register (Address = 0x07) [reset = 0x00]
            1. Table 28. Configuration Register Field Descriptions
          2. 8.6.1.2.2  Operation Control 1 (OP_CTRL_1) Register (Address = 0x08) [reset = 0x00]
            1. Table 29. Operation Control 1 Register Field Descriptions
          3. 8.6.1.2.3  Operation Control 2 (OP_CTRL_2) Register (Address = 0x09) [reset = 0x00]
            1. Table 30. Operation Control 2 Register Field Descriptions
          4. 8.6.1.2.4  Operation Control 3 (OP_CTRL_3) Register (Address = 0x0A) [reset = 0x00]
            1. Table 31. Operation Control 3 Register Field Descriptions
          5. 8.6.1.2.5  PWM Control 1 (PWM_CTRL_1) Register (Address = 0x0B) [reset = 0x00]
            1. Table 32. PWM Control 1 Register Field Descriptions
          6. 8.6.1.2.6  PWM Control 2 (PWM_CTRL_2) Register (Address = 0x0C) [reset = 0x00]
            1. Table 33. PWM Control 2 Register Field Descriptions
          7. 8.6.1.2.7  Free-Wheeling Control 1 (FW_CTRL_1) Register (Address = 0x0D) [reset = 0x00]
            1. Table 34. Free-Wheeling Control 1 Register Field Descriptions
          8. 8.6.1.2.8  Free-Wheeling Control 2 (FW_CTRL_2) Register (Address = 0x0E) [reset = 0x00]
            1. Table 35. Free-Wheeling Control 2 Register Field Descriptions
          9. 8.6.1.2.9  PWM Map Control 1 (PWM_MAP_CTRL_1) Register (Address = 0x0F) [reset = 0x00]
            1. Table 36. PWM Map Control 1 Register Field Descriptions
          10. 8.6.1.2.10 PWM Map Control 2 (PWM_MAP_CTRL_2) Register (Address = 0x10) [reset = 0x00]
            1. Table 37. PWM Map Control 2 Register Field Descriptions
          11. 8.6.1.2.11 PWM Map Control 3 (PWM_MAP_CTRL_3) Register (Address = 0x11) [reset = 0x00]
            1. Table 38. PWM Map Control 3 Register Field Descriptions
          12. 8.6.1.2.12 PWM Frequency Control (PWM_FREQ_CTRL) Register (Address = 0x12) [reset = 0x00]
            1. Table 39. PWM Frequency Control Register Field Descriptions
          13. 8.6.1.2.13 PWM Duty Control Channel 1 (PWM_DUTY_CH1) Register (Address = 0x13) [reset = 0x00]
            1. Table 40. PWM Duty Control Channel 1 Register Field Descriptions
          14. 8.6.1.2.14 PWM Duty Control Channel 2 (PWM_DUTY_CH2) Register (Address = 0x14) [reset = 0x00]
            1. Table 41. PWM Duty Control Channel 2 Register Field Descriptions
          15. 8.6.1.2.15 PWM Duty Control Channel 3 (PWM_DUTY_CH3) Register (Address = 0x15) [reset = 0x00]
            1. Table 42. PWM Duty Control Channel 3 Register Field Descriptions
          16. 8.6.1.2.16 PWM Duty Control Channel 4 (PWM_DUTY_CH4) Register (Address = 0x16) [reset = 0x00]
            1. Table 43. PWM Duty Control Channel 4 Register Field Descriptions
          17. 8.6.1.2.17 Slew Rate Control 1 (SR_CTRL_1) Register (Address = 0x17) [reset = 0x00]
            1. Table 44. Slew Rate Control 1 Register Field Descriptions
          18. 8.6.1.2.18 Slew Rate Control 2 (SR_CTRL_2) Register (Address = 0x18) [reset = 0x00]
            1. Table 45. Slew Rate Control 2 Register Field Descriptions
          19. 8.6.1.2.19 Open-Load Detect (OLD) Control 1 (OLD_CTRL_1) Register (Address = 0x19) [reset = 0x00]
            1. Table 46. Open-Load Detect (OLD) Control (OLD_CTRL_1) Register Field Descriptions
          20. 8.6.1.2.20 Open-Load Detect (OLD) Control 2 (OLD_CTRL_2) Register (Address = 0x1A) [reset = 0x00]
            1. Table 47. Open-Load Detect (OLD) Control (OLD_CTRL_2) Register Field Descriptions
          21. 8.6.1.2.21 Open-Load Detect (OLD) Control 3 (OLD_CTRL_3) Register (Address = 0x1B) [reset = 0x00]
            1. Table 48. Open-Load Detect (OLD) Control (OLD_CTRL_3) Register Field Descriptions
          22. 8.6.1.2.22 Open-Load Detect (OLD) Control 4 (OLD_CTRL_4) Register (Address = 0x24) [reset = 0x00]
            1. Table 49. Open-Load Detect (OLD) Control (OLD_CTRL_4) Register Field Descriptions
      2. 8.6.2 DRV8908-Q1, DRV8906-Q1 and DRV8904-Q1 Register Maps
        1. 8.6.2.1 Status Registers
          1. 8.6.2.1.1 IC Status (IC_STAT) Register (Address = 0x00) [reset = 0x00]
            1. Table 54. IC Status Register Field Descriptions
          2. 8.6.2.1.2 Overcurrent Protection (OCP) Status 1 (OCP_STAT_1) Register (Address = 0x01) [reset = 0x00]
            1. Table 55. Overcurrent Protection (OCP) Status 1 Register Field Descriptions
          3. 8.6.2.1.3 Overcurrent Protection (OCP) Status 2 (OCP_STAT_2) Register (Address = 0x02) [reset = 0x00]
            1. Table 56. Overcurrent Protection (OCP) Status 2 Register Field Descriptions
          4. 8.6.2.1.4 Overcurrent Protection (OCP) Status 3 (OCP_STAT_3) Register (Address = 0x03) [reset = 0x00]
            1. Table 57. Overcurrent Protection (OCP) Status 3 Register Field Descriptions
          5. 8.6.2.1.5 Open-Load Detect (OLD) Status 1 (OLD_STAT_1) Register (Address = 0x04) [reset = 0x00]
            1. Table 58. Open-Load Detect (OLD) Status 1 Register Field Descriptions
          6. 8.6.2.1.6 Open-Load Detect (OLD) Status 2 (OLD_STAT_2) Register (Address = 0x05) [reset = 0x00]
            1. Table 59. Open-Load Detect (OLD) Status 2 Register Field Descriptions
          7. 8.6.2.1.7 Open-Load Detect (OLD) Status 3 (OLD_STAT_3) Register (Address = 0x06) [reset = 0x00]
            1. Table 60. Open-Load Detect (OLD) Status 3 Register Field Descriptions
        2. 8.6.2.2 Control Registers
          1. 8.6.2.2.1  Configuration (CONFIG_CTRL) Register (Address = 0x07) [reset = 0x00]
            1. Table 62. Configuration Register Field Descriptions
          2. 8.6.2.2.2  Operation Control 1 (OP_CTRL_1) Register (Address = 0x08) [reset = 0x00]
            1. Table 63. Operation Control 1 Register Field Descriptions
          3. 8.6.2.2.3  Operation Control 2 (OP_CTRL_2) Register (Address = 0x09) [reset = 0x00]
            1. Table 64. Operation Control 2 Register Field Descriptions
          4. 8.6.2.2.4  Operation Control 3 (OP_CTRL_3) Register (Address = 0x0A) [reset = 0x00]
            1. Table 65. Operation Control 3 Register Field Descriptions
          5. 8.6.2.2.5  PWM Control 1 (PWM_CTRL_1) Register (Address = 0x0B) [reset = 0x00]
            1. Table 66. PWM Control 1 Register Field Descriptions
          6. 8.6.2.2.6  PWM Control 2 (PWM_CTRL_2) Register (Address = 0x0C) [reset = 0x00]
            1. Table 67. PWM Control 2 Register Field Descriptions
          7. 8.6.2.2.7  Free-Wheeling Control 1 (FW_CTRL_1) Register (Address = 0x0D) [reset = 0x00]
            1. Table 68. Free-Wheeling Control 1 Register Field Descriptions
          8. 8.6.2.2.8  Free-Wheeling Control 2 (FW_CTRL_2) Register (Address = 0x0E) [reset = 0x00]
            1. Table 69. Free-Wheeling Control 2 Register Field Descriptions
          9. 8.6.2.2.9  PWM Map Control 1 (PWM_MAP_CTRL_1) Register (Address = 0x0F) [reset = 0x00]
            1. Table 70. PWM Map Control 1 Register Field Descriptions
          10. 8.6.2.2.10 PWM Map Control 2 (PWM_MAP_CTRL_2) Register (Address = 0x10) [reset = 0x00]
            1. Table 71. PWM Map Control 2 Register Field Descriptions
          11. 8.6.2.2.11 PWM Map Control 3 (PWM_MAP_CTRL_3) Register (Address = 0x11) [reset = 0x00]
            1. Table 72. PWM Map Control 3 Register Field Descriptions
          12. 8.6.2.2.12 PWM Map Control 4 (PWM_MAP_CTRL_4) Register (Address = 0x12) [reset = 0x00]
            1. Table 73. PWM Map Control 4 Register Field Descriptions
          13. 8.6.2.2.13 PWM Frequency Control 1 (PWM_FREQ_CTRL_1) Register (Address = 0x13 [reset = 0x00]
            1. Table 74. PWM Frequency Control 1 Register Field Descriptions
          14. 8.6.2.2.14 PWM Frequency Control 2 (PWM_FREQ_CTRL_2) Register (Address = 0x14 [reset = 0x00]
            1. Table 75. PWM Frequency Control 2 Register Field Descriptions
          15. 8.6.2.2.15 PWM Duty Control Channel 1 (PWM_DUTY_CH1) Register (Address = 0x15) [reset = 0x00]
            1. Table 76. PWM Duty Control Channel 1 Register Field Descriptions
          16. 8.6.2.2.16 PWM Duty Control Channel 2 (PWM_DUTY_CH2) Register (Address = 0x16) [reset = 0x00]
            1. Table 77. PWM Duty Control Channel 2 Register Field Descriptions
          17. 8.6.2.2.17 PWM Duty Control Channel 3 (PWM_DUTY_CH3) Register (Address = 0x17) [reset = 0x00]
            1. Table 78. PWM Duty Control Channel 3 Register Field Descriptions
          18. 8.6.2.2.18 PWM Duty Control Channel 4 (PWM_DUTY_CH4) Register (Address = 0x18) [reset = 0x00]
            1. Table 79. PWM Duty Control Channel 4 Register Field Descriptions
          19. 8.6.2.2.19 PWM Duty Control Channel 5 (PWM_DUTY_CH5) Register (Address = 0x19) [reset = 0x00]
            1. Table 80. PWM Duty Control Channel 5 Register Field Descriptions
          20. 8.6.2.2.20 PWM Duty Control Channel 6 (PWM_DUTY_CH6) Register (Address = 0x1A) [reset = 0x00]
            1. Table 81. PWM Duty Control Channel 6 Register Field Descriptions
          21. 8.6.2.2.21 PWM Duty Control Channel 7 (PWM_DUTY_CH7) Register (Address = 0x1B) [reset = 0x00]
            1. Table 82. PWM Duty Control Channel 7 Register Field Descriptions
          22. 8.6.2.2.22 PWM Duty Control Channel 8 (PWM_DUTY_CH8) Register (Address = 0x1C) [reset = 0x00]
            1. Table 83. PWM Duty Control Channel 8 Register Field Descriptions
          23. 8.6.2.2.23 Slew Rate Control 1 (SR_CTRL_1) Register (Address = 0x1D [reset = 0x00]
            1. Table 84. Slew Rate Control 1 Register Field Descriptions
          24. 8.6.2.2.24 Slew Rate Control 2 (SR_CTRL_2) Register (Address = 0x1E) [reset = 0x00]
            1. Table 85. Slew Rate Control 2 Register Field Descriptions
          25. 8.6.2.2.25 Open-Load Detect (OLD) Control 1 (OLD_CTRL_1) Register (Address = 0x1F) [reset = 0x00]
            1. Table 86. Open-Load Detect (OLD) Control (OLD_CTRL_1) Register Field Descriptions
          26. 8.6.2.2.26 Open-Load Detect (OLD) Control 2 (OLD_CTRL_2) Register (Address = 0x20) [reset = 0x00]
            1. Table 87. Open-Load Detect (OLD) Control (OLD_CTRL_2) Register Field Descriptions
          27. 8.6.2.2.27 Open-Load Detect (OLD) Control 3 (OLD_CTRL_3) Register (Address = 0x21) [reset = 0x00]
            1. Table 88. Open-Load Detect (OLD) Control (OLD_CTRL_3) Register Field Descriptions
          28. 8.6.2.2.28 Open Load Detect (OLD) Control 4 (OLD_CTRL_4) Register (Address = 0x22) [reset = 0x00]
            1. Table 89. Open Load Detect (OLD) Control (OLD_CTRL_4) Register Field Descriptions
          29. 8.6.2.2.29 Open Load Detect (OLD) Control 5 (OLD_CTRL_5) Register (Address = 0x23) [reset = 0x00]
            1. Table 90. Open Load Detect (OLD) Control (OLD_CTRL_5) Register Field Descriptions
          30. 8.6.2.2.30 Open Load Detect (OLD) Control 6 (OLD_CTRL_6) Register (Address = 0x24) [reset = 0x00]
            1. Table 91. Open Load Detect (OLD) Control (OLD_CTRL_6) Register Field Descriptions
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Primary Application
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
          1. 9.2.1.2.1 Motor Current Rating
          2. 9.2.1.2.2 Power Dissipation
      2. 9.2.2 Alternative Application
        1. 9.2.2.1 Design Requirements
        2. 9.2.2.2 Detailed Design Procedure
          1. 9.2.2.2.1 H-Bridge Requirements for Parallel Operation
      3. 9.2.3 Application Curves
    3. 9.3 Thermal Application
      1. 9.3.1 Power Dissipation
        1. 9.3.1.1 Power Dissipation Due to Device On-State Resistance (RDS(ON))
        2. 9.3.1.2 Power Dissipation Due to Switching Losses
        3. 9.3.1.3 Power Dissipation Due to Quiescent Current
        4. 9.3.1.4 Total Power Dissipation
      2. 9.3.2 PCB Types
      3. 9.3.3 Thermal Parameters
      4. 9.3.4 Transient Thermal
      5. 9.3.5 Device Junction Temperature Estimation
  10. 10Power Supply Recommendations
    1. 10.1 Bulk Capacitance Sizing
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12デバイスおよびドキュメントのサポート
    1. 12.1 ドキュメントのサポート
      1. 12.1.1 関連資料
    2. 12.2 関連リンク
    3. 12.3 ドキュメントの更新通知を受け取る方法
    4. 12.4 コミュニティ・リソース
    5. 12.5 商標
    6. 12.6 静電気放電に関する注意事項
    7. 12.7 Glossary
  13. 13メカニカル、パッケージ、および注文情報
    1. 13.1 Package Option Addendum
      1. 13.1.1 Packaging Information
      2. 13.1.2 Tape and Reel Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Packaging Information

Orderable Device Status (1) Package Type Package Drawing Pins Package Qty Eco Plan (2) Lead/Ball Finish(4) MSL Peak Temp (3) Op Temp (°C) Device Marking(5)(6)
PDRV8912QPWPRQ1 PREVIEW HTSSOP PWP 24 2000 TBD CU
NIPDAU
Level-3-260C-168hrs -40 to 125 P8912
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PRE_PROD Unannounced device, not in production, not available for mass market, nor on the web, samples not available.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
space
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)
space
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
space
Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish value exceeds the maximum column width.
space
There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device
space
Multiple Device markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device.
Important Information and Disclaimer: The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.