10 Revision History
Changes from Revision Q (August 2018) to Revision R (October 2024)
- ドキュメント全体を通して容量性絶縁から絶縁バリアに参照を更新Go
- ドキュメント全体にわたって表、図、相互参照の採番方法を更新Go
- Updated Thermal Characteristics, Safety Limiting Values, and Thermal Derating Curves to provide more accurate system-level thermal calculationsGo
- Updated electrical and switching characteristics to match device performanceGo
Changes from Revision P (August 2018) to Revision Q (January 2021)
- Removed nominal specifications in the RECOMMENDED OPERATING CONDITIONS tableGo
Changes from Revision O (April 2017) to Revision P (August 2018)
- ドキュメント全体を通して、「(VDE V 0884-10):2006-12」を「DIN VDE V 0884-11:2017-01」に変更Go
- ドキュメント全体を通して、「Component Acceptance Notice 5A および IEC 60950-1 について CSA 認定済み」を「IEC 60950-1 および IEC 62368-1 について CSA 認定済み」に変更Go
- Added the basic insulation working voltage for CSA in the Safety-Related Certifications tableGo
- Changed the VDE certification number from 40016131 to 40047657 in the Safety-Related Certifications tableGo
- Changed the maximum propagation delay and pulse-width distortion in each Switching Characteristics tableGo
- Changed ISO722x to ISO7220 for all part numbers for the Channel-to-channel output skew parameter in each Switching Characteristic tableGo
- Added ± 10% for the VCC1 and VCC2 voltages in the condition statement of the Switching Characteristics—5-V VCC1 and VCC2 Supplies tableGo
Changes from Revision N (September 2015) to Revision O (April 2017)
- Changed the Dissipation Characteristics table to Power Ratings. Combined the DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 Insulation Characteristics table IEC Package Characteristics, and IEC 60664-1 Ratings Table in the Insulation Specifications table. Changed the Regulatory Information table to Safety-Related Certifications
Go
- Deleted the maximum surge voltage, 4000 VPK for VDE in the Safety-Related Certifications tableGo
- Changed the CSA information in the Safety-Related Certifications tableGo
Changes from Revision M (October 2014) to Revision N (September 2015)
- ドキュメント全体を通して、VDE 認証を「DIN EN 60747-5-5 (VDE 0884-5)」から「DIN V VDE V 0884-10 (VDE V 0884-10):2006-12」に変更。Go
- 「概略回路図」を高品質のバージョンに更新。Go
- Changed the max value of the IN and OUT voltage from 6 to VCC + 0.5 in the Absolute Maximum Ratings table.Go
- Added the JEDEC package dimensions note in the IEC Package Characteristics tableGo
- Changed the DTI test condition From: IEC 60112 / VDE 0303 Part 1 To: DIN EN 60112 (VDE 0303-11); IEC 60112Go
- Added = 150°C to insulation resistance test condition in the DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 Insulation Characteristics table.Go
- Changed L(I01) MIN value from 4.8 to 4 in the IEC Package Characteristics table.Go
- Added the DTI parameter to the IEC Package Characteristics table.Go
- Added table row with input side VCC = X to the ISO7220x or ISO7221x Function table.Go
Changes from Revision L (January 2012) to Revision M (August 2014)
- データシートのタイトルを『ISO722x デュアル チャネル デジタル アイソレータ』に変更Go
- 「ピン構成および機能」セクション、「取り扱い定格」表、「消費定格」表、「機能説明」セクション、「デバイスの機能モード」、「アプリケーションと実装」セクション、「電源に関する推奨事項」セクション、「レイアウト」セクション、「デバイスおよびドキュメントのサポート」セクション、「メカニカル、パッケージ、および注文情報」セクションを追加、「熱に関する情報」表を変更Go
- 「特長」セクションを更新Go
- 「説明」の 2 番目の文の「4000VPK」に「VDE 準拠」を追加Go
- Updated the Regulatory Information TableGo
- Added the min and max values to the Storage temperature parameter in the Absolute Maximum Ratings table.Go
- Changed in ROC table Max col, VIH row from VCC to 5.5Go
- Changed the L(I01) parameter name to external clearance (CLR) and L(I02) to external creepage (CPG). Also changed the input-to-output test voltage (VPR) parameter name to apparent charge (qpd)Go
- Changed the Device Options table, Input Threshold column from ≠ symbol to ~ symbol 6 places Go
- Changed the name of the Application Curve section to
Insulation Lifetime and moved to the Application Curves
sectionGo
- Changed Isolation Glossary
Go
Changes from Revision K (January 2010) to Revision L (January 2012)
- 「特長」を「3.3V または 5V 電源で動作」から「2.8V (Cグレード)、3.3V または 5V 電源で動作」に変更。Go
- 「特長」を「4000VPEAK 絶縁、560VPEAK VIORM」から「IEC 60747-5-2 (VDE 0884, Rev2) に準拠した 4000VPK VIOTM、560VPK VIORM」に変更Go
- Changed Note: (1) in the RECOMMENDED OPERATING CONDITIONS tableGo
- Added device options to VCC in the RECOMMENDED OPERATING CONDITIONS tableGo
- Changed the CTI MIN value From: ≥175 V To: ≥400 VGo
- Updated the Regulatory Information tableGo
- Changed Table Note: (1)Go
- Changed ICC1 and ICC2 test conditions in the 5-V tableGo
- Changed Table Note: (1)Go
- Changed ICC1 and ICC2 test conditions in the VCC1 at 5 V, VCC2 at 3.3 V tableGo
- Changed ICC1 and ICC2 test conditions in the VCC1 at 3.3 V, VCC2 at 5 V tableGo
- Changed Table Note (1)Go
- Changed ICC1 and ICC2 test conditions in the VCC1 and VCC2 at 3.3 V tableGo
- Changed Table Note (1)Go
- Added ELECTRICAL and Switching CHARACTERISTICS table for VCC1 and VCC2 at 2.8 V (ISO722xC-Only)Go
- Changed VCC Undervoltage Threshold vs Free-Air Temperature
Go
- Changed Failsafe Delay Time Test Circuit and Voltage Waveforms
Go
Changes from Revision J (May 2009) to Revision K ()
- Changed Note (2) From: Typical signaling rate under ideal conditions at 25°C. To: Typical signaling rate and Input pulse width are measured at ideal conditions at 25°C.Go
- Changed the RECOMMENDED OPERATING CONDITIONS so that Note (2) is associated with all device options in the Input pulse width and Signaling rateGo
- Changed column 2 of the AVAILABLE OPTIONS table From: Signaling Rate To: Max Signaling RateGo
Changes from Revision I (December 2008) to Revision J ()
- Changed ISO7221C Marked As column From: TI7221C To: I7221C in the AVAILABLE OPTIONS tableGo
Changes from Revision H (May 2008) to Revision I ()
- 「UL 1577 機能」の箇条書き項目に「IEC 61010-1、IEC 60950-1、CSA 認定済み」を追加Go
Changes from Revision G (March 2008) to Revision H ()
- Added Note: (1) to the RECOMMENDED OPERATING CONDITIONS tableGo
- Added Note: (1) to the ELECTRICAL CHARACTERISTICS: VCC1 and VCC2 at 5-V tableGo
- Added Note: (1) to the ELECTRICAL CHARACTERISTICS: VCC1 at 5 V, VCC2 at 3.3 V tableGo
- Added Note (1): to the ELECTRICAL CHARACTERISTICS: VCC1 at 3.3 V, VCC2 at 5 V tableGo
- Added Note (1): to the ELECTRICAL CHARACTERISTICS: VCC1 and VCC2 at 3.3 VGo
Changes from Revision F (August 2007) to Revision G ()
- デバイス番号 ISO7220B および ISO7221B をデータシートに追加Go
- 「特長」一覧に 5Mbps の信号速度を追加Go
- Added Part Numbers ISO7220B and ISO7221B to the ELECTRICAL CHARACTERISTICS: VCC1 and VCC2 at 5-V tableGo
- Added Part Numbers ISO7220B and ISO7221B to the ELECTRICAL CHARACTERISTICS: VCC1 at 5 V, VCC2 at 3.3 V tableGo
- Added Part Numbers ISO7220B and ISO7221B to the ELECTRICAL CHARACTERISTICS: VCC1 at 3.3 V, VCC2 at 5 V tableGo
- Added Part Numbers ISO7220B and ISO7221B to the ELECTRICAL CHARACTERISTICS: VCC1 and VCC2 at 3.3 VGo
- Added PROPAGATION DELAY vs FREE-AIR TEMPERATURE, ISO722xB, Propagation Delay vs Free-Air Temperature, ISO722xB
Go
- Added Part Numbers ISO7220B and ISO7221B to the AVAILABLE OPTIONS tableGo
Changes from Revision E (July 2007) to Revision F ()
- Added tsk(o) footnote to the SWITCHING CHARACTERISTICS: VCC1 and VCC2 at 5-V OPERATION tableGo
- Added tsk(pp) footnote to the SWITCHING CHARACTERISTICS: VCC1 and VCC2 at 5-V OPERATION tableGo
- Added tsk(pp) footnote to the SWITCHING CHARACTERISTICS: VCC1 at 5 V, VCC2 at 3.3 V OPERATION tableGo
- Added tsk(o) footnote to the SWITCHING CHARACTERISTICS: VCC1 at 5 V, VCC2 at 3.3 V OPERATION tableGo
- Added tsk(pp) footnote to the SWITCHING CHARACTERISTICS: VCC1 at 3.3 V, VCC2 at 5 V OPERATION tableGo
- Added tsk(o) footnote to the SWITCHING CHARACTERISTICS: VCC1 at 3.3 V, VCC2 at 5 V OPERATION tableGo
- Added tsk(pp) footnote to the SWITCHING CHARACTERISTICS tableGo
- Changed 3.3-VRMS Supply Current vs Signaling Rate - Re-scaled the Y-axisGo
- Changed 5-VRMS Supply Current vs Signaling Rate - New CurvesGo
Changes from Revision D (June 2007) to Revision E ()
- Changed 3.3-VRMS Supply Current vs Signaling Rate - New CurvesGo
- Changed 5-VRMS Supply Current vs Signaling Rate - Re-scaled the Y-axis Go
Changes from Revision C (May 2007) to Revision D ()
- Changed Typical ISO7220x Circuit Hook-Up - Pin 2 (INA) label From: OUTPUT to INPUTGo
Changes from Revision B (May 2007) to Revision C ()
- Added the Signaling rate values to the RECOMMENDED OPERATING CONDITIONS tableGo
- Changed the IEC 60664-1 RATINGS TABLE - Specification I-III test conditions From: Rated mains voltage ≤150 VRMS To: Rated mains voltage ≤300 VRMS. Added a row for the I-II specificationsGo
- Added ISO722xM Jitter vs Signaling Rate cross reference to the Peak-to-peak eye-pattern jitter of the SWITCHING CHARACTERISTICS tableGo
- Added Time-Dependent Dielectric Breakdown Test Results
Go
Changes from Revision A (August 2006) to Revision B ()
- Added the TYPICAL CHARACTERISTIC CURVES to the data sheet.Go
- Added the PARAMETER MEASUREMENT INFORMATION to the data sheetGo
- Added the APPLICATION INFORMATION section to the data sheetGo
- Added the ISOLATION GLOSSARY section to the data sheet Go
Changes from Revision * (July 2006) to Revision A ()
- 「UL 1577 機能」の箇条書き項目から「および CSA 認定済み」を削除Go
- Added option A to the AVAILABLE OPTIONS tableGo