JAJSH42D February   2016  – October 2021 TCAN1042-Q1 , TCAN1042G-Q1 , TCAN1042GV-Q1 , TCAN1042H-Q1 , TCAN1042HG-Q1 , TCAN1042HGV-Q1 , TCAN1042HV-Q1 , TCAN1042V-Q1

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. Device Comparison Table
  6. Pin Configurations and Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 ESD Ratings, Specifications
    4. 7.4 Recommended Operating Conditions
    5. 7.5 Thermal Information
    6. 7.6 Power Rating
    7. 7.7 Electrical Characteristics
    8. 7.8 Switching Characteristics
    9. 7.9 Typical Characteristics
  8. Parameter Measurement Information
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1 TXD Dominant Timeout (DTO)
      2. 9.3.2 Thermal Shutdown (TSD)
      3. 9.3.3 Undervoltage Lockout
      4. 9.3.4 Unpowered Device
      5. 9.3.5 Floating Terminals
      6. 9.3.6 CAN Bus Short Circuit Current Limiting
      7. 9.3.7 Digital Inputs and Outputs
        1. 9.3.7.1 Devices with VCC Only (Devices without the "V" Suffix):
        2. 9.3.7.2 Devices with VIO I/O Level Shifting (Devices with "V" Suffix):
    4. 9.4 Device Functional Modes
      1. 9.4.1 CAN Bus States
      2. 9.4.2 Normal Mode
      3. 9.4.3 Standby Mode
        1. 9.4.3.1 Remote Wake Request via Wake Up Pattern (WUP) in Standby Mode
      4. 9.4.4 Driver and Receiver Function Tables
  10. 10Application Information Disclaimer
    1. 10.1 Application Information
    2. 10.2 Typical Applications
      1. 10.2.1 Design Requirements
        1. 10.2.1.1 Bus Loading, Length and Number of Nodes
      2. 10.2.2 Detailed Design Procedures
        1. 10.2.2.1 CAN Termination
      3. 10.2.3 Application Curves
  11. 11Power Supply Recommendations
  12. 12Device and Documentation Support
    1. 12.1 Receiving Notification of Documentation Updates
    2. 12.2 サポート・リソース
    3. 12.3 Trademarks
    4. 12.4 Electrostatic Discharge Caution
    5. 12.5 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • D|8
  • DRB|8
サーマルパッド・メカニカル・データ
発注情報

ESD Ratings, Specifications

TEST CONDITIONSVALUEUNIT
D (SOIC) Package
System Level Electro-Static Discharge (ESD)CAN bus terminals (CANH, CANL) to GNDSAE J2962-2 per ISO 10605: Powered Air Discharge±15000V
SAE J2962-2 per ISO 10605: Powered Contact Discharge±8000
System Level Electro-Static Discharge (ESD)CAN bus terminals (CANH, CANL) to GNDIEC 61000-4-2: Unpowered Contact Discharge±15000V
IEC 61000-4-2: Powered on Contact Discharge±8000
System Level Electrical fast transient (EFT)CAN bus terminals (CANH, CANL) to GNDIEC 61000-4-4: Criteria A±4000V
ISO7637-2 Transients according to GIFT - ICT CAN EMC test specification(1)CAN bus terminals (CANH, CANL) to GNDPulse 1–100V
Pulse 2+75
Pulse 3a–150
Pulse 3b+100
ISO7637-3 TransientsCAN bus terminals (CANH, CANL) to GNDDirect Coupling Capacitor "Slow Transient Pulse" with 100 nF coupling capacitor - Powered±85
DRB (VSON) Package
System Level Electro-Static Discharge (ESD)CAN bus terminals (CANH, CANL) to GNDSAE J2962-2 per ISO 10605: Powered Air Discharge±15000V
SAE J2962-2 per ISO 10605: Powered Contact Discharge±8000
System Level Electro-Static Discharge (ESD)CAN bus terminals (CANH, CANL) to GNDIEC 61000-4-2: Unpowered Contact Discharge±14000V
IEC 61000-4-2: Powered on Contact Discharge±8000
System Level Electrical fast transient (EFT)CAN bus terminals (CANH, CANL) to GNDIEC 61000-4-4: Criteria A±4000V
ISO7637-2 Transients according to GIFT - ICT CAN EMC test specification(1)CAN bus terminals (CANH, CANL) to GNDPulse 1–100V
Pulse 2+75
Pulse 3a–150
Pulse 3b+100
ISO7637-3 TransientsCAN bus terminals (CANH, CANL) to GNDDirect Coupling Capacitor "Slow Transient Pulse" with 100 nF coupling capacitor - Powered±85
ISO7637 is a system level transient test. Results given here are specific to the GIFT-ICT CAN EMC Test specification conditions. Different system level configurations may lead to different results.