JAJSK01E april   2011  – december 2020 TLV803 , TLV853

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Revision History
  6. Device Comparison
  7. Pin Configuration and Functions
    1.     Pin Functions
  8. Specifications
    1. 7.1 Absolute Maximum Ratings #GUID-24157BEB-92B8-46F1-A3B7-B7A06F8BDB0C/SLVSA033153
    2. 7.2 ESD Ratings
    3. 7.3 Thermal Information
    4. 7.4 Recommended Operating Conditions
    5. 7.5 Electrical Characteristics
    6. 7.6 Switching Characteristics
    7. 7.7 Typical Characteristics
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 VDD Transient Rejection
      2. 8.3.2 Reset During Power Up and Power Down
      3. 8.3.3 Bidirectional Reset Pins
    4. 8.4 Device Functional Modes
      1. 8.4.1 Normal Operation (VDD > Power-Up Reset Voltage)
      2. 8.4.2 Power On Reset (VDD < Power-Up Reset Voltage)
  10. Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 Monitoring Multiple Supplies
      2. 9.1.2 Output Level Shifting
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
  11. 10Power Supply Recommendations
  12. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  13. 12Device and Documentation Support
    1. 12.1 Device Support
      1. 12.1.1 Development Support
        1. 12.1.1.1 Evaluation Modules
        2. 12.1.1.2 Spice Models
    2. 12.2 Documentation Support
      1. 12.2.1 Related Documentation
    3. 12.3 Related Links
    4. 12.4 サポート・リソース
    5. 12.5 Trademarks
    6. 12.6 静電気放電に関する注意事項
    7. 12.7 用語集
  14. 13Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Absolute Maximum Ratings(1)

over operating junction temperature range (unless otherwise noted)
MINMAXUNIT
VoltageVDD(2)06.5V
All other pins(2)–0.3+6.5
CurrentMaximum low output current, IOL5mA
Maximum high output current, IOH–5
Input clamp current, IIK (VI < 0 or VI > VDD)±20
Output clamp current, IOK (VO < 0 or VO > VDD)±20
TemperatureOperating junction temperature range, TJ–40125°C
Storage temperature range, Tstg–65150
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
All voltage values are with respect to GND. For reliable operation the device should not be operated at 6.5 V for more than t = 1000h continuously