JAJSL81C february 2021 – july 2023 TMUX7308F , TMUX7309F
PRODUCTION DATA
The TMUX7308F and TMUX7309F enter into the Fault mode when any of the input signals on the source (Sx) pins exceed VDD or VSS by a threshold voltage VT. Under the overvoltage condition, the switch input experiencing the fault automatically turns OFF regardless of the logic status, and the source pin becomes high impedance with a negligible amount of leakage current flowing through the switch. When the fault channel is selected by the logic control, the drain pin (D or Dx) is pulled to the supply that was exceeded through a 40 kΩ internal resistor.
The overvoltage protection is provided only for the source (Sx) input pins. The drain (D or Dx) pin, if used as a signal input, must stay in between VDD and VSS at all times since no overvoltage protection is implemented on the drain pin.