SNVSCN9A September 2024 – December 2024 TPS3423 , TPS3424
PRODUCTION DATA
tSP= 50ms and tLP= 2sec can be selected through the factory programmed option or placing capacitor at the SPT and LPT pin for programable option. Leave the SPT and LPT pin open as shown in Figure 8-1 for factory programmed timing option. Equation 1 and Equation 2 shows the value for capacitor at SPT and LPT pin respectively for programming tSP= 50ms and tLP= 2sec in cap programable option.