JAJSJ23F September 2019 – October 2023 TPS62860 , TPS62861
PRODUCTION DATA
In normal operation, the device does not force PWM operation during VOUT change after VSEL toggle or I2C command. For ramping down, this mode provides the remaining energy, stored in the output capacitor to the load of the DC/DC and save battery charge. See Figure 9-14.
Through I2C, the device can be set to forced PWM (FPWM) switching during output voltage change. This allows a controlled ramp of VOUT up and especially down, regardless of the load condition. See Figure 9-15.
This feature follows the internal I2C ramp and is only recommended for the setting 1 mV/µs and 0.1 mV/µs. During the faster slopes (10 mV/µs and 5 mV/µs), the mode is likely to be left before the voltage reached the new target value.